Powered by GoogleTranslate

Inspection Detail

Inspection: 124725979 - Able Steel Erectors Inc

Inspection Information - Office: Or-E-Portland - Safety 1 1054111

 

Inspection Nr: 124725979
Report ID: 1054111
Date Opened: 03/28/1996

Site Address:
Able Steel Erectors Inc
28455 Sw Barber St
Wilsonville, OR 97070

Mailing Address:
Po Box 1989, Clackamas, OR 97015

Union Status: NonUnion

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/05/1996

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/11/2000


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $5,000 $0 $0 $0 $0 $5,000
Current Penalty $1,500 $0 $0 $0 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 701076001 B C 09/10/1996 09/13/1996 $1,500 $5,000 $0 09/25/1996 L - State Settlement  

Investigation Summary

Investigation Nr: 788307
Event: 03/27/1996
Employee injured in fall from roof

At approximately 1:30 p.m. on March 27, 1996, Employee #1 was applying mastic to metal for installation on a butler type building. He walked backward off the roof and fell 36 ft to a gravel surface. There was a fall protection system installed and the employee was wearing a harness but was not tied off. He suffered bruises, fractured ribs, a collapsed lung, a ruptured spleen, and a concussion, but is expected to recover.

Keywords: INSTALLING, ROOF, WORK RULES, CONSTRUCTION, FALL, FALL PROTECTION, WALKING BACKWARD, TIE-OFF

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 124725979 Hospitalized injury Other Structural metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.