Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1243748.015 - Douglas N. Higgins Inc; Mckenna Contracting Llc; Dba D.N. Higgins

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 1243748.015
Report ID: 0418800
Date Opened: 01/16/2017

Site Address:
Douglas N. Higgins Inc; Mckenna Contracting Llc; Dba D.N. Higgins
Ifo 181 Long Key Road Lake Surprise
Key Largo, FL 33037

Mailing Address:
3390 Travis Pointe Road, Ann Arbor, MI 48108

Union Status: NonUnion

SIC:

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Fat/Cat

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/16/2017

Emphasis:

Case Closed: 12/20/2022


Related Activity
Type Activity Nr Safety Health
Accident 1173315
Inspection 1207971 Yes
Inspection 1203449 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 10 10
Current Violations 10 10
Initial Penalty $119,507 $0 $0 $0 $0 $119,507
Current Penalty $119,507 $0 $0 $0 $0 $119,507
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19101200 E01 07/14/2017 07/20/2017 $12,675 $12,675 $0 Z - Issued  
2. 01001B Serious 19101200 G01 07/14/2017 08/09/2017 $0 $0 $0 Z - Issued  
3. 01001C Serious 19101200 H01 07/14/2017 08/09/2017 $0 $0 $0 Z - Issued  
4. 01002A Serious 19261203 E02 II 07/14/2017 07/20/2017 $5,432 $5,432 $0 Z - Issued  
5. 01002B Serious 19261204 C06 07/14/2017 07/20/2017 $0 $0 $0 Z - Issued  
6. 01003 Serious 19261203 E02 III 07/14/2017 07/20/2017 $12,675 $12,675 $0 Z - Issued  
7. 01004 Serious 19261204 B 07/14/2017 07/20/2017 $12,675 $12,675 $0 Z - Issued  
8. 01005 Serious 19261204 C04 07/14/2017 07/20/2017 $12,675 $12,675 $0 Z - Issued  
9. 01006 Serious 19261204 D01 07/14/2017 07/20/2017 $12,675 $12,675 $0 Z - Issued  
10. 01007 Serious 19261204 D09 07/14/2017 07/20/2017 $12,675 $12,675 $0 Z - Issued  
11. 01008 Serious 19261204 I 07/14/2017 07/20/2017 $12,675 $12,675 $0 Z - Issued  
12. 01009A Serious 19261205 A 07/14/2017 07/20/2017 $12,675 $12,675 $0 Z - Issued  
13. 01009B Serious 19261205 F 07/14/2017 07/20/2017 $0 $0 $0 Z - Issued  
14. 01010A Serious 19261207 A 07/14/2017 07/20/2017 $12,675 $12,675 $0 Z - Issued  
15. 01010B Serious 19261207 C 07/14/2017 07/26/2017 $0 $0 $0 Z - Issued  

Investigation Summary

Investigation Nr: 96757.015
Event: 01/16/2017
Employee is asphyxiated inside manhole and is killed

At 8:30 a.m. on January 16, 2017, an employee was descending a ladder into a manhole to repair a leaking pipe. The employee was overcome by gasses inside the manhole and was asphyxiated by hydrogen sulfide and methane gas.

Keywords: Asphyxiated, Confined Space, Hydrogen Sulfide, Manhole, Methane

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1243748.015 34 M Fatality Pipelayer
2 1243748.015 24 M Fatality Pipelayer
3 1243748.015 49 M Fatality Pipelayer
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.