Inspection Detail
Inspection: 1238215.015 - Dominguez Welding Llc
Inspection Information - Office: Denver Area Office
Site Address:
Dominguez Welding Llc
Wcr 13 & Wcr 32, E ? Mi, S ? Mi, W 0.2 Mi 40.210783, -104.932077
Mead, CO 80542
Mailing Address:
15641 Dale Ave, Fort Lupton, CO 80621
Union Status: NonUnion
SIC:
NAICS: 213112/Support Activities for Oil and Gas Operations
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/02/2017
Emphasis: L:Oilgas
Case Closed: 02/19/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Inspection | 1237560 | Yes | |
Inspection | 1237410 | Yes | |
Inspection | 1237778 | Yes | |
Inspection | 1241352 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 5 | 5 | ||||
Current Violations | 5 | 5 | ||||
Initial Penalty | $13,039 | $0 | $0 | $0 | $0 | $13,039 |
Current Penalty | $4,000 | $0 | $0 | $0 | $0 | $4,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19101200 E01 | 11/16/2017 | 11/30/2018 | $1,000 | $2,173 | $0 | 12/11/2017 | F - Formal Settlement | |
2. | 01001B | Serious | 19101200 G08 | 11/16/2017 | 11/30/2018 | $0 | $0 | $0 | 12/11/2017 | F - Formal Settlement | |
3. | 01002 | Serious | 19260020 B02 | 11/16/2017 | 11/30/2018 | $1,000 | $3,803 | $0 | 12/11/2017 | F - Formal Settlement | |
4. | 01003 | Serious | 19260351 E | 11/16/2017 | 11/30/2018 | $500 | $1,630 | $0 | 12/11/2017 | F - Formal Settlement | |
5. | 01004A | Serious | 19260352 A | 11/16/2017 | 11/30/2018 | $1,000 | $3,803 | $0 | 12/11/2017 | F - Formal Settlement | |
6. | 01004B | Serious | 19260651 G01 III | 11/16/2017 | 11/30/2018 | $0 | $0 | $0 | 12/11/2017 | F - Formal Settlement | |
7. | 01005A | Serious | 19260651 J02 | 11/16/2017 | $500 | $1,630 | $0 | 12/11/2017 | F - Formal Settlement | ||
8. | 01005B | Serious | 19260651 K01 | 11/16/2017 | 11/30/2018 | $0 | $0 | $0 | 12/11/2017 | F - Formal Settlement |
Investigation Summary
At 3:15 p.m. on May 25, 2017, an employee was welding on polycoated 2 in. pipe in a trench at an oil and gas production tank battery. An explosion occurred and the employee received significant burns to the back, arms, and head.
Keywords: Arm, Back, Burn, Explosion, Head, Oil Tank
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1238215.015 | 40 | M | Hospitalized injury | Welders and cutters |