Powered by GoogleTranslate

Inspection Detail

Inspection: 123811085 - E I Du Pont De Nemours & Co Inc

Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance

 

Inspection Nr: 123811085
Report ID: 0452110
Date Opened: 08/03/1993

Site Address:
E I Du Pont De Nemours & Co Inc
4200 Campground Road
Louisville, KY 40216

Mailing Address:
, , 00000

Union Status: Union

SIC:2869

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/28/1994

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 10/17/1994


Related Activity
Type Activity Nr Safety Health
Accident 360208946
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 1 8
Current Violations 6 1 7
Initial Penalty $19,550 $0 $0 $850 $0 $20,400
Current Penalty $16,575 $0 $0 $850 $0 $17,425
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100119 L01 01/28/1994 02/03/1994 $2,975 $2,975 $0 -  
2. 01002 Serious 19100119 L03 01/28/1994 02/03/1994 $2,975 $2,975 $0 -  
3. 01003 Serious 19100120 Q01 01/28/1994 02/09/1994 $2,975 $2,975 $0 -  
4. 01004 Serious 19100120 Q06 III 01/28/1994 09/10/1994 $2,975 $2,975 $0 P - Petition to Mod Abatement  
5. 01005 Serious 19100120 Q09 I 01/28/1994 09/10/1994 $2,975 $2,975 $0 P - Petition to Mod Abatement  
6. 01006 Serious 19100134 E03 01/28/1994 02/24/1994 $2,975 $2,975 $0 A - Amendment Citation has been deleted.
7. 01007 Serious 19100134 E03 I 01/28/1994 02/09/1994 $1,700 $1,700 $0 -  
8. 02001 Other 19100119 C02 01/28/1994 02/03/1994 $850 $850 $0 -  

Investigation Summary

Investigation Nr: 14262109
Event: 07/29/1993
Employees overcome by release of hazardous materials

At approximately 10:05 p.m. on July 29, 1993, a fitting connecting flexible hose to a make-up tank (st-1) broke, releasing what was initially reported to be hydrogen chloride, although it was subsequently determined that other materials such as chloroform, hydrogen fluoride, antimony, and lithium were also in the tank. Employee #1 had been working in the general area and was overcome by the release on the way to the freon administrative/control building. Employee #2 went to check on the release and also was overcome on his way to the administrative/control building. Employee #3 was overcome by a vapor cloud as he entered the maintenance shop to obtain ppe. Employees #4, #5, and #6 responded to the release in chemical suits and were sent to the hospital due to heat stress from working in the encapsulated suits.

Keywords: HEAT, CONDUCTIVE HOSE, VENTILATION, PPE, HYDROGEN CHLORIDE, HYDROGEN FLUORIDE, GAS, HOSE, AIR CONTAMINATION, CHEMICAL VAPOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123811085 Non Hospitalized injury Other Miscellaneous plant and system operators
2 123811085 Non Hospitalized injury Other Miscellaneous plant and system operators
3 123811085 Non Hospitalized injury Other Miscellaneous plant and system operators
4 123811085 Non Hospitalized injury Heat Exhaustion Supervisors, production occupations
5 123811085 Non Hospitalized injury Heat Exhaustion Machinery maintenance occupations
6 123811085 Non Hospitalized injury Heat Exhaustion Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.