Powered by GoogleTranslate

Inspection Detail

Inspection: 123788531 - Littleford-Day, Incorporated

Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance

 

Inspection Nr: 123788531
Report ID: 0452110
Date Opened: 07/21/1994

Site Address:
Littleford-Day, Incorporated
7451 Empire Drive
Florence, KY 41042

Mailing Address:
, , 00000

Union Status: Union

SIC:3556

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/21/1994

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/07/1996


Related Activity
Type Activity Nr Safety Health
Accident 361314750
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $3,050 $0 $0 $0 $0 $3,050
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 338003101 A 08/24/1994 09/20/1994 $1,525 $3,000 $0 09/15/1994 R - Review Commission  
2. 01001B Serious 19100147 C01 08/24/1994 09/20/1994 $0 $0 $0 09/15/1994 R - Review Commission  
3. 01002A Serious 19101030 C01 I 08/24/1994 10/04/1994 $1,525 $1,500 $0 09/15/1994 R - Review Commission  
4. 01002B Serious 19101030 D01 08/24/1994 10/04/1994 $0 $0 $0 09/15/1994 R - Review Commission  
5. 01002C Serious 19101030 G02 IIA 08/24/1994 10/04/1994 $0 $0 $0 09/15/1994 R - Review Commission  

Investigation Summary

Investigation Nr: 782730
Event: 07/20/1994
EMPLOYEE DECAPTITATED WHEN MIXER STARTED

An assembler was manufacturing an industrial mixer. He had his head inside the mixer, checking to see if the batch release door was flush. Apparently, he meant to press the "discharge open" button to open the door he was checking. This button was next to the start button for the mixer. The employee pressed the start button by mistake; and the mixer started up, decapitating the employee. An interlock switch had been installed to prevent the mixer from starting with the side door open. Unfortunately, it malfunctioned.

Keywords: START BUTTON, MIXER, INTERLOCK, LOCKOUT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123788531 Fatality Amputation Assemblers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close