Inspection: 123654352 - Mclane Construction Co.

Inspection Information - Office: Va-E-Richmond (Regional Office) - Safety 0355111

 

Inspection Nr: 123654352
Report ID: 0355111
Date Opened: 10/15/1992

Site Address:
Mclane Construction Co.
Johnson Elementary School/Bethlehem Rd.
Glen Allen, VA 23230

Mailing Address:
2036 Botetourt St., Richmond, VA 23220

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/02/1992

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/04/1995


Related Activity
Type Activity Nr Safety Health
Accident 360299929
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 1
Initial Penalty $2,500 $140,000 $0 $0 $0 $142,500
Current Penalty $0 $15,000 $0 $0 $0 $15,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious ELEC0409 A01 04/13/1993 04/19/1993 $2,500 $2,500 $0 04/20/1993 Y - State Decision Citation has been deleted.
2. 02001 Willful ELEC040802 04/13/1993 04/19/1993 $15,000 $70,000 $0 04/20/1993 Y - State Decision  
3. 02002 Willful ELEC040802 04/13/1993 04/19/1993 $70,000 $70,000 $0 04/20/1993 Y - State Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 895102
Event: 10/15/1992
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

AN EMPLOYEE WAS USING AN EXCAVATOR TO LAY A GRAVEL BED IN A 5-FOOT-DEEP, 2-FOOT-WIDE PIPE TRENCH. A 5-FOOT, 5-INCH-HIGH METAL GRAVEL BUCKET HAD BEEN SECURED TO THE CASE TRACK EXCAVATOR TO PERFORM THIS OPERATION. THE EXCAVATOR HAD BEEN SET UP BENEATH A 34.5-KILOVOLT OVERHEAD POWER LINE LOCATED 26 FEET ABOVE THE PAVEMENT. AS IT WAS DUMPING GRAVEL FROM THE BUCKET INTO THE TRENCH, THE BOOM OF THE EXCAVATOR CONTACTED ONE OF THE 19.9-KILOVOLT-TO-GROUND PHASE CONDUCTORS, AND THE EMPLOYEE WAS ELECTROCUTED.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E C, MECH MAT HANDLING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 123654352 Fatality Electric Shock Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.