Powered by GoogleTranslate

Inspection Detail

Inspection: 122467632 - Evergreen Irrigation Inc.

Inspection Information - Office: Madison Area Office

 

Inspection Nr: 122467632
Report ID: 0523300
Date Opened: 07/31/1997

Site Address:
Evergreen Irrigation Inc.
1650 Lee Lane
Beloit, WI 53511

Mailing Address:
126 N. Madison Street, Rockford, WI 61107

Union Status: NonUnion

SIC:1711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/26/1997

Emphasis:

Case Closed: 12/05/1997


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $1,500 $0 $0 $0 $0 $1,500
Current Penalty $900 $0 $0 $0 $0 $900
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260416 A03 08/26/1997 08/29/1997 $900 $1,500 $0 I - Informal Settlement  
2. 02001 Other 19040002 A 08/26/1997 09/05/1997 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14372908
Event: 07/30/1997
ELECTRIC SHOCK - CONTACT WITH ENERGIZED PARTS

An installer for an irrigation firm was tracing an underground power line leading from one parking lot light pole to another in preparation for installing an automatic sprinkler system at an occupational medicine clinic. He removed the coils from the base of one light pole and started to read a paper tag wrapped around a conductor. The tag described which pole was next in the series. As he touched the tag, he received an electric shock, which arrested his breathing and his heart. The job supervisor was able to knock the employee from the pole. Nurses at the site were able to resuscitate the employee, and he was hospitalized for his injury. He had been performing his work for about 3 years. He was not wearing any personal protective equipment.

Keywords: ELEC PROTECT EQUIP, ELECTRICAL, ELECTRICAL WORK, LOCKOUT, STREETLIGHTING, E C, ELECTRIC CONDUCTOR, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 122467632 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close