Powered by GoogleTranslate

Inspection Detail

Inspection: 122040058 - Super Steel Products Corp.

Inspection Information - Office: Milwaukee Area Office

 

Inspection Nr: 122040058
Report ID: 0523400
Date Opened: 04/03/1994

Site Address:
Super Steel Products Corp.
7900 West Tower Avenue
Milwaukee, WI 53223

Mailing Address:
, , 00000

Union Status: Union

SIC:3441

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/17/1994

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/24/1994


Related Activity
Type Activity Nr Safety Health
Accident 360407126
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $3,375 $0 $0 $0 $0 $3,375
Current Penalty $3,375 $0 $0 $0 $0 $3,375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C04 I 05/19/1994 05/24/1994 $2,500 $2,500 $0 I - Informal Settlement  
2. 01002 Serious 19100147 C06 II 05/19/1994 06/01/1994 $875 $875 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14367445
Event: 04/02/1994
Employee killed when caught in machine door

Because there were no witnesses, the specific aspects of this accident are unknown. Employee #1 was last seen setting up the stacker unit for the light gauge coil line. The unit was fully set up with the exception of the spacer to reduce the size of the stacking area. The employee was probably planning to install the spacer to ensure that the steel would be properly stacked. He moved the operator side access door control lever to raise the door and heard the air flow as the compressed air was released from the cylinder side, which was holding the door. The compressed air then was flowing into the other side of the cylinder to raise the door. The door was jammed, and Employee #1, not noticing that it was not open, entered the hazardous area. Either he caused the door to open or the compressed air reached a pressure great enough to overcome the jamming action. The door opened rapidly and Employee #1 was caught between the frame of the unit and the door. He died.

Keywords: WORK RULES, JAMMED, CAUGHT BETWEEN, HIGH PRESSURE, DOOR, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 122040058 Fatality Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.