Powered by GoogleTranslate

Inspection Detail

Inspection: 121976237 - Ross Incineration Services Inc.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 121976237
Report ID: 0524700
Date Opened: 10/12/1994

Site Address:
Ross Incineration Services Inc.
36790 Giles Rd.
Grafton, OH 44044

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:4953

NAICS: 0 


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/09/1994

Emphasis:

Case Closed: 08/23/1995


Related Activity
Type Activity Nr Safety Health
Complaint 76724236 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 2 2
Initial Penalty $8,000 $0 $0 $0 $0 $8,000
Current Penalty $2,973 $0 $0 $0 $0 $2,973
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100120 G03 I 12/07/1994 12/12/1994 $0 $1,500 $0 02/24/1995 F - Formal Settlement Citation has been deleted.
2. 01002 Serious 19100106 E06 12/07/1994 07/19/1995 $1,973 $2,750 $0 02/24/1995 F - Formal Settlement  
3. 01003A Serious 19100120 J02 IV 12/07/1994 12/27/1994 $0 $2,750 $0 02/24/1995 F - Formal Settlement Citation has been deleted.
4. 01003B Serious 19100120 J02 VI 12/07/1994 12/27/1994 $0 $0 $0 02/24/1995 F - Formal Settlement Citation has been deleted.
5. 01004A Serious 19100132 A 12/07/1994 12/12/1994 $1,000 $1,000 $0 -  

Investigation Summary

Investigation Nr: 695395
Event: 10/12/1994
EMPLOYEE SUFFERS THIRD DEGREE BURNS IN FIRE

Employee #1 was preparing a 55-gallon drum of spent chemicals for incineration when the lid of the drum popped open due to internal pressure and sprayed the chemical on him. Vapors apparently spread to the incinerator wall and ignited due to its approximately 450 degrees F temperature. incinerator wall temperature. A fireball engulfed Employee #1 and ignited his clothing. Employee #1 suffered third-degree burns.

Keywords: BURN, HEAT, VAPOR, FIRE, INCINERATOR, PRESSURE RELEASE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 121976237 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close