Powered by GoogleTranslate

Inspection Detail

Inspection: 121974588 - Ideal Electric Company

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 121974588
Report ID: 0524700
Date Opened: 02/01/1996

Site Address:
Ideal Electric Company
330 E. First St.
Mansfield, OH 44902

Mailing Address:
, , 00000

Union Status: Union

SIC:3621

NAICS: 0 


Inspection Type: Complaint

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/24/1996

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/19/1996


Related Activity
Type Activity Nr Safety Health
Complaint 74655531
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 4 4
Initial Penalty $27,575 $0 $0 $0 $0 $27,575
Current Penalty $9,500 $0 $0 $0 $0 $9,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100106 D02 I 05/16/1996 06/18/1996 $0 $6,300 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 19100106 E06 I 05/16/1996 06/18/1996 $2,375 $6,300 $0 I - Informal Settlement  
3. 01003 Serious 19100106 E06 II 05/16/1996 06/18/1996 $2,375 $6,300 $0 I - Informal Settlement  
4. 01004 Serious 19100132 A 05/16/1996 06/18/1996 $2,375 $6,300 $0 I - Informal Settlement  
5. 01005 Serious 19100106 E02 IVD 05/16/1996 06/18/1996 $2,375 $2,375 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202085049
Event: 11/30/1995
Employee burned when xylene vapors ignite

Employee #1 had just finished using xylene, a flammable liquid, to clean a paint spray unit. The chemical was stored in a room that contained several baking ovens. After returning the xylene, Employee #1 opened the door of oven #431 to see if any motors were being baked out. Not seeing any, he closed the door and turned to leave the room. As he did so, the xylene vapors that had been pulled into the oven by its ventilation system ignited. The ensuing flash fire and explosion blew out the oven doors and the fire spread out into the room, igniting Employee #1's clothing. He sustained first-, second-, and third-degree burns to his face, ears, neck, and both arms.

Keywords: BURN, CLOTHING, HEAD, FLAMMABLE VAPORS, OVEN, WORK RULES, XYLENE, FIRE, EXPLOSION, CLEANING FLUID

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 121974588 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.