Inspection: 121934459 - Genie Co.

Inspection Information - Office: Cleveland Area Office

 

Inspection Nr: 121934459
Report ID: 0522300
Date Opened: 11/07/1995

Site Address:
Genie Co.
2850 Gilchrist Road Bldg 9&10
Akron, OH 44305

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3669

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/19/1996

Emphasis:

Case Closed: 04/01/1996


Related Activity
Type Activity Nr Safety Health
Accident 361848526
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 4 1 5
Initial Penalty $15,950 $0 $0 $0 $0 $15,950
Current Penalty $5,475 $0 $0 $0 $0 $5,475
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100151 A 02/01/1996 02/06/1996 $0 $5,000 $0 I - Informal Settlement  
2. 01002 Serious 19100157 G01 02/01/1996 03/05/1996 $850 $1,700 $0 I - Informal Settlement  
3. 01003A Serious 19101000 A02 02/01/1996 02/06/1996 $2,500 $5,000 $0 I - Informal Settlement  
4. 01003B Serious 19101000 E 02/01/1996 02/06/1996 $0 $0 $0 -  
5. 01004A Serious 19101030 F01 I 02/01/1996 02/06/1996 $1,063 $2,125 $0 I - Informal Settlement  
6. 01004B Serious 19101030 G02 I 02/01/1996 02/06/1996 $0 $0 $0 -  
7. 01005 Serious 19101200 H 02/01/1996 03/05/1996 $1,062 $2,125 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 688895
Event: 11/02/1995
Employee hospitalized after exposure to carbon monoxide

After work on November 1, 1995, Employee #1 sought medical attention. Although he is a non-smoker, his carboxyhemoglobin level was 11 percent. He informed the employer the next day. Several other employees then went to various hospital emergency rooms. Employees #1 through #12 were admitted and treated overnight. Some of the employees were given hypobaric treatment. Their carboxyhemoglobin levels were 10 percent to 16.7 percent. The employer did carbon monoxide monitoring and found levels to be 85 to 132 ppm in and around the production area. Heaters were inspected and two were taken out of service until repaired. Lift truck tailpipes were tested and adjusted. Four propane lift trucks were replaced with electric trucks. Fresh air is provided through overhead doors and pedestal. Eight hour TWA carbon monoxide levels were measured at 1 to 10 ppm. There is now a related 11(c) case for an employee terminated for excessive absenteeism due to another incident of high carboxyhemoglobin levels in December.

Keywords: AIR CONTAMINATION, CARBOXYHEMOGLOBIN, OVEREXPOSURE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
2 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
3 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
4 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
5 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
6 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
7 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
8 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
9 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
10 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
11 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
12 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.