Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 120539218 - E & C Construction Inc

Inspection Information - Office: Tenn Cmpl Sfty 4

Nr: 120539218Report ID: 0454714Open Date: 08/12/1994

E & C Construction Inc
Pope'S Plant Farm
Alcoa, TN 37853
Union Status: NonUnion
SIC: 1799/Special Trade Contractors, Not Elsewhere Classified
Mailing: Route 4, Box 382, Andalusia, AL 36420

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:08/12/1994
Planning Guide: Safety-Construction Close Case:03/26/2003

Related Activity:TypeIDSafetyHealth
 Accident360287478    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $3,500 $0 $0 $0 $0 $3,500
Current Penalty $3,500 $0 $0 $0 $0 $3,500
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19260404 B01 I 09/01/1994 09/12/1994 $1,500 $1,500 $0 09/29/1994 R - Review Commission
  2. 01002 Serious 19260404 F06 09/01/1994 09/12/1994 $1,000 $1,000 $0 09/29/1994 R - Review Commission
  3. 01003 Serious 19260405 G02 IV 09/01/1994 09/12/1994 $1,000 $1,000 $0 09/29/1994 R - Review Commission

Accident Investigation Summary
Summary Nr: 170122444Event: 08/12/1994Electric Shock - Ground Fault In Attachment Plug
An employee was standing on a 10-foot-tall metal stepladder. He was using a portable electric tool plugged into an extension cord set to fasten screws to the metal framework for a greenhouse. The attachment plug on the tool's power supply cord was loosely connected to the connector on the cord set. The blade for the ungrounded circuit conductor, which was exposed by the gap between the plug and cord connector, contacted the metal ladder. When the employee contacted the greenhouse's metal framework while he was standing on the ladder, he was electrocuted.
Keywords: e gi iii, electrical, stepladder, cord set, electrocuted, attachment plug, ground fault, cord connector, metal ladder
Inspection Degree Nature Occupation
1 120539218 Fatality Electric Shock Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.