Powered by GoogleTranslate

Inspection Detail

Inspection: 120459565 - H. G. Reynolds Co.

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 120459565
Report ID: 0454510
Date Opened: 03/18/1993

Site Address:
H. G. Reynolds Co.
1561 Columbia Hwy.
Aiken, SC 29801

Mailing Address:
113 Contract Dr., Aiken, SC 29801

Union Status: NonUnion

SIC:1541

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/23/1993

Emphasis:

Case Closed: 06/23/1993


Related Activity
Type Activity Nr Safety Health
Inspection 120459581
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $500 $0 $0 $0 $0 $500
Current Penalty $200 $0 $0 $0 $0 $200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 04001 Serious 19260059 E02 05/13/1993 05/18/1993 $200 $500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 675231
Event: 03/18/1993
Employees overcome by chemical vapor

At approximately 7:30 a.m. on March 18, 1993, an on-site contractor that was building an addition to the prime site began applying concrete sealant containing trimethylbenzene, ethylbenzene, xylene, and mineral spirits to a final 4 ft by 150 ft strip of concrete floor. The permanent wall between the plant stockroom and the new addition had been removed and a plastic enclosure had been constructed to contain dust in the new work area. At approximately 8:00, a supervisor from the plant complained to the contractor about smelling fumes in the plant. Exhaust fans were placed near the roll-up doors to draw the fumes outdoors. At approximately 8:45, Employee #3, who was working in the stockroom, became ill and went to the breakroom, where she was treated by EMTs. Employees then began to evacuate the building. Employees #1, #2, and #3 were hospitalized and 26 employees were treated for nausea, headaches, and dizziness. Employees #1, #2, and #3 were all recovering from respiratory illnesses, and according to the MSDS, the chemicals in the sealant were known to aggravate pre-existing respiratory health problems. The contractor had not made a copy of the MSDS available to the prime site to adequately protect their employees. It was observed that there was a strong negative pressure in the plant and fumes were pulled directly into the stockroom through holes in the plastic; however, levels of exposure could not be measured as the inspection took place after the plant had been evacuated and ventilated.

Keywords: EXHAUST SYSTEM, RESPIRATORY, WORK RULES, XYLENE, INHALATION, TOXIC FUMES, CONCRETE, VENTILATION, CHEMICAL VAPOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120459565 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.