Inspection Detail
Inspection: 120343116 - Chiron Corporation
Inspection Information - Office: Oakland District Office
Site Address:
Chiron Corporation
Bldg Q, 3rd Fl., Room Q3-16
Emeryville, CA 94608
Mailing Address:
4650 Horton St, Emeryville, CA 94608
Union Status: NonUnion
SIC:8731
NAICS: 541710/ Research and Development in the Physical, Engineering, and Life Sciences
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 12/11/2003
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 06/23/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361495641 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $875 | $0 | $875 |
| Current Penalty | $0 | $0 | $0 | $875 | $0 | $875 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A04 | 12/16/2003 | 01/30/2004 | $875 | $875 | $0 | - |
Investigation Summary
Employee #1 was installing new equipment on cleaning process lines that carry a sodium hydroxide solution with a pH greater than 13. Employee #1 used the wrong pump that was rated at 25 psi. In order to make it work Employee #1 assembled the hoses with adapters and clamps. When Employee #1 hooked-up the hose to the rinse spigot that had 35 psi to 45 psi of pressure, backpressure built up in the pump. The hose was blown off the spigot causing the chemical to splash on both eyes. Employee #1 was fully protected, including safety glasses, and she immediately flushed her eyes. Employee #1 sustained severe corneal damage disabling her with marked photophobia and diminished visual acuity since the date of the injury. Employee #1 was treated but was not hospitalized.
Keywords: EYE, HOSE, CHEMICAL BURN, PUMP, PRESSURE RELEASE, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120343116 | Non Hospitalized injury | Burn(Chemical) | Chemical technicians |
Translate