Inspection: 120313655 - Ca Transportation-Electrical Maintenance

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 120313655
Report ID: 0950643
Date Opened: 06/03/2002

Site Address:
Ca Transportation-Electrical Maintenance
Rinaldi On-Ramp To Southbound 405 Fwy.
Chatsworth, CA 91345

Mailing Address:
7300 E. Bandini Boulevard, Commerce, CA 90040

Union Status: Union

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: StateGovt

Safety/Health: Safety

Close Conference: 10/02/2002

Planning Guide: Safety-Construction

Emphasis: S:Construction (Cship)

Case Closed: 10/15/2004


Related Activity
Type Activity Nr Safety Health
Accident 362519423
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations
Initial Penalty $0 $0 $0 $1,270 $0 $1,270
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 4002 A 10/02/2002 10/07/2002 $0 $635 $0 05/01/2003 J - ALJ Decision Citation has been deleted.
2. 01002 Other 3203 A04 10/02/2002 11/20/2002 $0 $635 $0 05/01/2003 J - ALJ Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 201114170
Event: 04/08/2002
Employee injured when fingertips caught in rotating blade

At 9:00 a.m. on April 4, 2002, Employee #1, was servicing an electrical cabinet used to meter cars on the ramp to a freeway. He was using a 120-volt, Weedeater Barracuda 2595 Superblower, Mulching Type 1, #01026D, to clean out the cabinet. The electric blower had a plastic cover that guarded the plastic blades of the unit but the cover kept popping open. Employee #1 said that when he tried to close the cover, the index and middle fingers of his left hand became caught in the blades. The tip of his index finger and part of the tip of his middle finger were amputated. According to Employee #1, the causal factor was a defective guard that kept on popping open. The employer said the guard was not present at the accident site but was found the day of the accident in another vehicle at the yard where the employees report to work. Employee #1's leadman and supervisor said that Employee #1 transfered his equipment from one vehicle to a second vehicle on the day of the accident, and they believed the guard was left behind. The employer was cited for a violation, general, of T8CCR 4002(a), for not having the blower guarded. It was not established with reasonable certainty that the employer knew the guard was defective or missing prior to the accident. The employer was also cited for a violation, general, of T8CCR 3203(a)(4), for not conducting periodic inspections to identify the condition of the equipment and tools.

Keywords: PORTABLE POWER TOOL, AMPUTATED, COVER, FINGER, GUARD, ROTATING KNIFE, WORK RULES, CAUGHT BY, CONSTRUCTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120313655 Hospitalized injury Amputation Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.