Powered by GoogleTranslate

Inspection Detail

Inspection: 120296629 - Flat And Vertical Inc

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 120296629
Report ID: 0950635
Date Opened: 07/09/1997

Site Address:
Flat And Vertical Inc
970 E 236th St
Carson, CA 90746

Mailing Address:
760 N Eckhoff Av, Orange, CA 90746

Union Status: NonUnion

SIC:1795

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/06/1997

Emphasis:

Case Closed: 09/16/1998


Related Activity
Type Activity Nr Safety Health
Accident 362027377
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $10,500 $0 $0 $135 $0 $10,635
Current Penalty $4,400 $0 $0 $135 $0 $4,535
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 08/12/1997 09/08/1997 $135 $135 $0 -  
2. 02001 Serious 1534 A 08/12/1997 08/15/1997 $450 $3,500 $0 10/21/1997 J - ALJ Decision  
3. 03001 Serious 1534 B 08/12/1997 08/15/1997 $3,500 $3,500 $0 10/21/1997 J - ALJ Decision  
4. 04001 Serious 1935 A 08/12/1997 08/15/1997 $450 $3,500 $0 10/21/1997 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201030665
Event: 06/05/1997
Employee burned in flash fire

At approximately 9:00 a.m. on June 5, 1997, Employee #1 was cutting concrete at a construction site. He reached into the storage cabinet of truck #12 to turn off the water pump for the concrete saw. As he turned the ON/OFF power switch, a spark ignited the flammable vapors within the cabinet generated by the storage of open, 5-gallon gas cans. A flash fire ensued, and Employee #1 sustained third-degree burns to his right arm, chest, and face. Paramedics transported him to the Torrance Memorial Burn Center.

Keywords: BURN, FLAMMABLE LIQUID, FLAMMABLE VAPORS, WORK RULES, FIRE, CONSTRUCTION, SPARK, FACE, GASOLINE, GAS CAN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120296629 Hospitalized injury Burn/Scald(Heat) Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close