Powered by GoogleTranslate

Inspection Detail

Inspection: 120260328 - Mc Gill Corporation

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 120260328
Report ID: 0950644
Date Opened: 08/05/1999

Site Address:
Mc Gill Corporation
4056 Easy Street
El Monte, CA 91731

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5031

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/05/1999

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/11/2006


Related Activity
Type Activity Nr Safety Health
Accident 362545980
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 2 4 6
Initial Penalty $8,180 $0 $0 $945 $0 $9,125
Current Penalty $3,310 $0 $0 $695 $0 $4,005
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5144 K01 D 11/05/1999 12/06/1999 $260 $315 $0 12/03/1999 F - Formal Settlement  
2. 01002 Other 4973 11/05/1999 12/06/1999 $0 $315 $0 12/03/1999 F - Formal Settlement  
3. 01003 Other 4650 E 11/05/1999 12/06/1999 $175 $315 $0 12/03/1999 F - Formal Settlement  
4. 02001 Other 4838 A 11/05/1999 12/06/1999 $260 $1,590 $0 12/03/1999 F - Formal Settlement  
5. 03001 Serious 4845 B 11/05/1999 12/06/1999 $1,310 $1,590 $0 12/03/1999 F - Formal Settlement  
6. 04001 Serious 3328 F 11/05/1999 12/06/1999 $2,000 $5,000 $0 12/03/1999 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201792355
Event: 08/03/1999
Employee Injured When Struck By Falling Object

At approximately 9:40 a.m. on August 3, 1999, Employee #1 was removing a large part, called a block, from dip tank Number 1 when the hoist pulley broke causing the block to swing horizontally and strike him in the chest. Employee #1 was pinned between the block and a large floor-mounted vent called a "purger." Coworkers saw employee #1 staggering out of the dip tank Number 1 area and provided assistance. Employee #1 had sustained serious injuries including a broken breast-bone and broken ribs. Employee #1 was hospitalized for 4 days. The employer had had an outside machine shop fabricate a new pulley about two weeks before the accident. After the accident the employer examined the broken pulley and determined it was not made to the same specifications as the original and because the specifications were not the same, grease was prevented from lubricating the parts. Therefore, the pulley seized and broke. The employer had failed to ensure that the new pulley was made to the original specifications.

Keywords: CHEST, FRACTURE, PINNED, EQUIPMENT FAILURE, HOIST, RIB, DIP TANK, STRUCK BY, PULLEY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120260328 Hospitalized injury Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close