Inspection Detail
Inspection: 120240767 - Netronics Systems Inc
Inspection Information - Office: Santa Ana District Office
Site Address:
Netronics Systems Inc
2355 N Tustin
Orange, CA 92667
Mailing Address:
3305 E Mira Loma #174, Anaheim, CA 92806
Union Status: NonUnion
SIC:4899
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/06/2000
Emphasis:
Case Closed: 02/02/2001
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362395113 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $12,600 | $0 | $0 | $390 | $0 | $12,990 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 04/17/2000 | 04/20/2000 | $0 | $225 | $0 | D - Govt Dismissed | ||
| 2. | 01002 | Other | 1509 A | 04/17/2000 | 05/20/2000 | $0 | $165 | $0 | D - Govt Dismissed | ||
| 3. | 02001 | Serious | 1670 A | 04/17/2000 | 05/05/2000 | $0 | $12,600 | $0 | D - Govt Dismissed |
Investigation Summary
Employee #1 was installing a satellite dish when he inadvertently stepped off roof. Employee #1 fell 13 ft and suffered fatal head injury.
Keywords: FRACTURE, HEAD, ROOF, SLIP, FALL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120240767 | Fatality | Fracture | Telephone installers and repairers |
Translate