Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 120185376 - Benicia Fabrication & Machine Inc.

Inspection Information - Office: Ca Concord

Nr: 120185376Report ID: 0950622Open Date: 02/03/1994

Benicia Fabrication & Machine Inc.
101 East Channel Road
Benicia, CA 94510
Union Status: NonUnion
SIC: 3498/Fabricated Pipe and Pipe Fittings

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:03/14/1994
Close Case:07/10/1995

Related Activity:TypeIDSafetyHealth
 Accident362107641    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $5,000 $0 $0 $0 $0 $5,000
Current Penalty $0 $0 $0 $0 $0 $0
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
Deleted 1. 01001 Serious 5420 A02 03/24/1994 02/03/1994 $0 $5,000 $0 04/01/1994 J - ALJ Decision

Accident Investigation Summary
Summary Nr: 170620033Event: 01/15/1994Employee Burned When Tube Containing Flammables Burns
On January 15, 1994, Employee #1, from Benicia Fabrication & Machine, Inc., was observing another employee cutting U-tubes on a heat exchanger using an air arc. A closed tube containing flammables burst into flames, inflicting second- and third-degree burns to Employee #1's chest and underarms.
Keywords: burn, chest, fire, laceration, heat exchanger, arm
Inspection Degree Nature Occupation
1 120185376 Hospitalized injury Burn/Scald(Heat) Miscellaneous hand working occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close