Inspection: 120148523 - Faencal Tartaric Products Inc

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 120148523
Report ID: 0950625
Date Opened: 01/02/2003

Site Address:
Faencal Tartaric Products Inc
2886 S Maple
Fresno, CA 93725

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2099

NAICS: 311941/ Mayonnaise, Dressing, and Other Prepared Sauce Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/04/2003

Emphasis:

Case Closed: 07/06/2006


Related Activity
Type Activity Nr Safety Health
Accident 361711823
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 3 3 6
Initial Penalty $17,100 $0 $0 $610 $0 $17,710
Current Penalty $9,450 $0 $0 $610 $0 $10,060
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 03/27/2003 04/29/2003 $175 $175 $0 -  
2. 01002 Other 3203 A04 B 03/27/2003 04/29/2003 $350 $350 $0 -  
3. 01003 Other 5194 E01 03/27/2003 04/29/2003 $85 $85 $0 -  
4. 02001 Serious 5144 D02 A12 03/27/2003 04/29/2003 $3,150 $3,150 $0 -  
5. 03001 Serious 5157 C01 03/27/2003 04/29/2003 $3,150 $10,800 $0 04/21/2003 J - ALJ Decision  
6. 04001 Serious 5416 C 03/27/2003 04/29/2003 $3,150 $3,150 $0 -  

Investigation Summary

Investigation Nr: 201083631
Event: 11/26/2002
Two employees burned by fire in tank

At 2:00 p.m. on November 26, 2002, Employee #1 was checking the dryness of a polymeric adhesive (3M Scotch-Grip Rubber and Gasket Adhesive #847-L) which had been applied six hours earlier to the inside walls of a cylindrical product mixing tank measuring 12-ft in height and 9-ft in diameter, with a 3-ft-diameter access opening. A non-intrinsically safe 115V Dayton Electric Dust Collector (Model Number 6C503B; Serial Number CP) was being inappropriately used to ventilate the hazardous atmosphere inside the tank containing Acetone, Toluene, and Methyl Ethyl Ketone. A non-intrinsically safe electric drop light was also being used inside the tank at the time. Employee #2, the plant manager, was supervising Employee #1 from the top of the tank. Employee #1 had descended an aluminum extension ladder to the bottom of the tank and checked the lower portions of tank walls for dryness. While ascended the ladder, he touching the walls with his finger tips, and the atmosphere in his immediate proximity ignited. Employee #1 was hospitalized with second- and third-degree burns to his upper torso, hands, arms, legs. Employee #2, who reached into the tank to assist Employee #1 out of the tank, sustained minor burns to his face, forearms, fingers, and hands.

Keywords: BURN, TEMPORARY LIGHTING, VENTILATION, LADDER, TORSO, ARM, FACE, TANK, HAND, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120148523 Non Hospitalized injury Burn/Scald(Heat) Supervisors, production occupations
2 120148523 Hospitalized injury Burn/Scald(Heat) Not specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.