Powered by GoogleTranslate

Inspection Detail

Inspection: 120080676 - Polycarbon Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 120080676
Report ID: 0950643
Date Opened: 11/02/1995

Site Address:
Polycarbon Inc.
28176 N. Ave. Stanford
Valencia, CA 91355

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3295

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/22/1996

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362293755
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $5,000 $0 $0 $750 $0 $5,750
Current Penalty $5,000 $0 $0 $750 $0 $5,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 14301 B 01/22/1996 01/31/1996 $300 $300 $0 03/20/1996 W - Empr Withdrew  
2. 01002 Other 3314 A 01/22/1996 01/31/1996 $450 $450 $0 03/20/1996 W - Empr Withdrew  
3. 02001 Serious 4002 A 01/22/1996 01/31/1996 $5,000 $5,000 $0 03/20/1996 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 170151567
Event: 09/02/1995
Employee's finger amputated when caught in moving machinery

On September 2, 1995, Employee #1, of Polycarbon, Inc., Valencia, CA, was changing the bag on a vacuum collection machine for scrap graphite from the carbon fiber and graphite production machinery when he noticed that material was stuck in the hopper. In order to free the jammed scrap graphite, he inserted his right hand into an outlet without shutting off and locking out the rotating valve inside the outlet. A guard at the bottom of the outlet designed to keep employees' hands away from the rotary valve had been removed. When Employee #1 reached into the outlet, his right index fingertip made contact with the rotating vanes of the rotary valve, causing a severe laceration and subsequent amputation of the first joint of the right index finger. The causal factors for the accident include the failure to ensure that the guard on the outlet was in place and the failure to de-energize the rotary valve before reaching into the vacuum system discharge outlet.

Keywords: ROTATING PARTS, AMPUTATED, FINGER, WORK RULES, JAMMED, LOCKOUT, VALVE, UNGUARDED, HOPPER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120080676 Hospitalized injury Amputation Production helpers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.