Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - South

 

Inspection Nr: 120060561
Report ID: 0950645
Date Opened: 12/19/1995

Site Address:
Unocal
2555 Willow Road
Arroyo Grande, CA 93420

Mailing Address:
, , 00000

Union Status: Union

SIC:2911

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/11/1996

Emphasis:

Case Closed: 12/18/1996


Related Activity
Type Activity Nr Safety Health
Accident 362486813
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $5,000 $0 $0 $0 $0 $5,000
Current Penalty $5,000 $0 $0 $0 $0 $5,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 6816 A 01/19/1996 02/21/1996 $5,000 $5,000 $0 03/29/1996 J - ALJ Decision  

Investigation Summary

Investigation Nr: 170739262
Event: 12/07/1995
Employee burned by hot water from leaking valve

At approximately 7:00 p.m. on December 7, 1995, Employee #1 and two coworkers were removing coke from a drum, an 80 ft high by 10 ft diameter tank. The employer has two drums and the coke removal process is done approximately every 18 hours on each drum. There are two written procedures for this job: the drum switch, which involves cooling and draining; and hot bolting bottom head, which involves removing and installing the top drum head and bottom head. The removal process was being done on the D102 drum, which normally takes approximately 3 hours to complete. When Employee #1 and the coworkers were installing the bottom head, hot water came out the bottom head, which had an approximately 4 in. gap before it was bolted up. Employee #1 was unable to get away and could not see where he was going. He climbed through a guardrail and fell approximately 24 ft. He was hospitalized. The 14 in. overhead line, which contained some hot water, had a leaky valve and steam was going into the line. There was no blind on the line and the line was not disconnected or disaligned. Also, the bleeder between the two steam seals was closed. A citation was issued to the employer.

Keywords: BURN, LEAK, WORK RULES, EQUIPMENT FAILURE, STEAM, VALVE, HOT WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120060561 Hospitalized injury Burn/Scald(Heat) Miscellaneous plant and system operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.