Powered by GoogleTranslate

Inspection Detail

Inspection: 119989507 - Southwest Marine Inc

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 119989507
Report ID: 0950632
Date Opened: 10/29/1992

Site Address:
Southwest Marine Inc
Foot Of Sampson St
San Diego, CA 92113

Mailing Address:
Po Box 13308, San Diego, CA 92170

Union Status: NonUnion

SIC:3731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/27/1993

Emphasis:

Case Closed: 05/24/1995


Related Activity
Type Activity Nr Safety Health
Accident 361270135
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 11 5 16
Current Violations 1 4 5
Initial Penalty $45,875 $0 $0 $2,950 $0 $48,825
Current Penalty $2,500 $0 $0 $3,250 $0 $5,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 B 04/28/1993 05/28/1993 $0 $500 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
2. 01002 Other 14301 B 04/28/1993 05/18/1993 $375 $500 $0 05/06/1993 W - Empr Withdrew  
3. 01003 Other 23400026 04/28/1993 05/28/1993 $375 $375 $0 05/06/1993 W - Empr Withdrew  
4. 01004 Other 2811 04/28/1993 05/28/1993 $0 $375 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
5. 01005 Other 3203 A 04/28/1993 05/28/1993 $0 $1,200 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
6. 02001 Serious 2714 A 04/28/1993 05/28/1993 $0 $6,250 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
7. 03001 Serious 2835 H 04/28/1993 05/28/1993 $2,500 $2,500 $0 05/06/1993 W - Empr Withdrew  
8. 04001 Serious 2940 B 04/28/1993 05/28/1993 $0 $3,500 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
9. 05001 Serious 2940 D 04/28/1993 05/28/1993 $0 $5,000 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
10. 06001 Serious 29400003 04/28/1993 05/28/1993 $0 $5,000 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
11. 07001 Other 2940 B 04/28/1993 05/28/1993 $1,000 $5,000 $0 05/06/1993 J - ALJ Decision  
12. 08001 Serious 2943 G01 04/28/1993 05/28/1993 $0 $5,000 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
13. 09001 Serious 2944 C01 04/28/1993 05/28/1993 $0 $3,125 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
14. 10001 Other 3203 A04 04/28/1993 05/28/1993 $1,500 $3,500 $0 05/06/1993 J - ALJ Decision  
15. 11001 Serious 3314 C 04/28/1993 05/28/1993 $0 $3,500 $0 05/06/1993 J - ALJ Decision Citation has been deleted.
16. 12001 Serious 3382 A 04/28/1993 05/28/1993 $0 $3,500 $0 05/06/1993 J - ALJ Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 170611206
Event: 10/28/1992
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

An electrical technician was assigned to work alone on an electric power mound. He was performing preventative maintenance on the 12-kilovolt unit during damp weather conditions. The area in which the employee was working was poorly illuminated. Additionally, the employer did not provide documentation for any training that had been provided to the employee. The employee was electrocuted while he was working on the unit. Numerous burns on his wrist and along his body indicated that he contacted an energized part while he was lying on a wet surface. A rag with burn holes and a spray can of solvent were found, indicating that he might have been manually cleaning the ceramic terminals and checking them for cracks. The oil switch to the mound was purportedly in the open position; however, the panel lights indicated that the circuit breaker controlling electric power to the mound was closed. No signs, tags, or locks had been used.

Keywords: E GI IV, ELECTRICAL, INSULATOR, ELECTRICIAN, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, LIGHTING, ELEC CIRC PART--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119989507 Fatality Bruise/Contus/Abras Electrical and electronic technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.