Powered by GoogleTranslate

Inspection Detail

Inspection: 119988103 - Aquanetics System

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 119988103
Report ID: 0950632
Date Opened: 07/15/1994

Site Address:
Aquanetics System
5252 Lovelock St
San Diego, CA 92110

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3999

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/15/1994

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/07/1996


Related Activity
Type Activity Nr Safety Health
Accident 362249815
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $4,000 $0 $0 $275 $0 $4,275
Current Penalty $2,000 $0 $0 $275 $0 $2,275
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 01/10/1995 01/10/1995 $275 $275 $0 01/30/1995 W - Empr Withdrew  
2. 02001 Serious 4184 A 01/10/1995 01/10/1995 $2,000 $4,000 $0 01/30/1995 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 171004633
Event: 04/22/1994
Employee's fingertip amputated by table saw blade

At approximately 12:35 p.m. on April 22, 1994, Employee #1, a 30-year-old production worker for Aquanetics Systems, was operating a table saw to cut foam packing material. The table saw did not have a guard over its 10 inch blade, which was exposed one inch above the table surface. Employee #1's left hand contacted the exposed blade when he reached to retrieve kicked back material. Coworkers in the immediate area came to his aid and took him into an office while 911 was called. His left middle fingertip, which had been amputated to the first knuckle, was recovered and placed in ice. Paramedics arrived in a few minutes and transported Employee #1 to a local hospital. The guard had been removed for some time and could not be found. The saw was taken out of service and locked in a storage room, and the foam cutting operation was stopped. Aquanetics Systems now has its foam inserts delivered in the precut sizes required for packing shipping containers.

Keywords: AMPUTATED, FINGER, WORK RULES, STRUCK AGAINST, BLADE, UNGUARDED, TABLE SAW

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119988103 Hospitalized injury Amputation Production helpers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.