Powered by GoogleTranslate

Inspection Detail

Inspection: 119976355 - Sverdrup Technology Inc

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 119976355
Report ID: 0950625
Date Opened: 10/14/1998

Site Address:
Sverdrup Technology Inc
Test Stand 1d
Edwards Afb, CA 93524

Mailing Address:
8 Draco Dr Bldg 8350, Edwards Afb, CA 93524

Union Status: NonUnion

SIC:8731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/06/1998

Emphasis:

Case Closed: 07/22/1999


Related Activity
Type Activity Nr Safety Health
Accident 362050908
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $5,000 $0 $0 $375 $0 $5,375
Current Penalty $5,000 $0 $0 $375 $0 $5,375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 11/12/1998 11/17/1998 $375 $375 $0 -  
2. 02001 Serious 342 A 11/12/1998 11/17/1998 $5,000 $5,000 $0 -  

Investigation Summary

Investigation Nr: 201081114
Event: 05/19/1998
EMPLOYEE INJURED IN FALL INTO PIT

On May 19, 1998, Employee #1 was installing a hinge on the filter box of the dehumidifying unit. To facilitate access to the filters, Employee #1 was standing on grating which covered the pit. This unit was located directly over a pit. All the area over the pit except for a sixteen-square-foot area was covered with steel grating. This uncovered area was directly in back of where Employee #1 was standing while performing his task. Employee #1 fell into the 11-ft-2-in.-deep utility pit and sustained fractures to his wrist, left hip and trauma to his face.

Keywords: DECKING, GRATING, PIT, FALL, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119976355 Hospitalized injury Fracture Heating, air conditioning, and refrig. mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.