Powered by GoogleTranslate

Inspection Detail

Inspection: 119958098 - Ameron, Concrete And Steel Pipe Group

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 119958098
Report ID: 0950633
Date Opened: 12/10/1996

Site Address:
Ameron, Concrete And Steel Pipe Group
12455 Arrow Route
Etiwanda, CA 91739

Mailing Address:
, , 00000

Union Status: Union

SIC:3443

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/18/1996

Emphasis:

Case Closed: 08/24/2008


Related Activity
Type Activity Nr Safety Health
Accident 362038283
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $5,000 $0 $0 $185 $0 $5,185
Current Penalty $750 $0 $0 $150 $0 $900
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3328 G 02/10/1997 02/13/1997 $150 $185 $0 03/31/1997 W - Empr Withdrew  
2. 02001 Serious 3328 E 02/10/1997 02/13/1997 $750 $5,000 $0 03/31/1997 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 170846075
Event: 08/14/1996
Employee's right foot severed when forming case falls

At approximately 7:00 a.m. on August 14, 1996, Employee #1 was with a coworker in the verticast area, preparing to strip test concrete cylinders. He was located between the steam cell wall and one end of a 16 ft high by 14 ft deep forming case, while his coworker was unbolting the forming case at its other end. The case had twenty-two 7 in. long bolts, and two 12 in. long by 1 1/4 in. diameter spring bolts that prevented the case from opening more than 6 in. The case was placed on a 22 in. high pedestal that consisted of six vertical support brackets. As the concrete was being poured, the two spring bolts apparently came loose, possibly from vibrations. When Employee #1 opened the last small bolt, the case sprang open and fell. It landed on Employee #1's right foot, severing it near the ankle. Causal factors in this accident included the forming case not being secured by the two large spring bolts, and the case being unstable because it was placed on six supports. The employer was cited for a serious violation of T8CCR 3328(e), and a general violation of T8CCR 3328 (g).

Keywords: SEVERED, UNSECURED, WORK RULES, VIBRATIONS, BOLT, STRUCK BY, FALLING OBJECT, FOOT, UNSTABLE POSITION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119958098 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close