Powered by GoogleTranslate

Inspection Detail

Inspection: 119950004 - Mag Instrument, Inc.

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 119950004
Report ID: 0950633
Date Opened: 08/10/2000

Site Address:
Mag Instrument, Inc.
1652 S. Sacramento Ave.
Ontario, CA 91761

Mailing Address:
1950 S. Sterling, Ontario, CA 91761

Union Status: NonUnion

SIC:3648

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/11/2000

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362479594
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $20,700 $0 $0 $300 $0 $21,000
Current Penalty $20,700 $0 $0 $300 $0 $21,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 12/12/2000 12/26/2000 $300 $300 $0 01/31/2001 J - ALJ Decision  
2. 02001 Serious 4002 A 12/12/2000 12/26/2000 $2,700 $2,700 $0 01/31/2001 J - ALJ Decision  
3. 03001 Serious 3314 A 12/12/2000 12/26/2000 $18,000 $18,000 $0 01/31/2001 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201153756
Event: 07/07/2000
Employee's finger amputated in screw machine

At approximately 12:00 noon on July 7, 2000, Employee #1 was making adjustments on the brake band of Acme Gridley Automatics screw machine, model RB-6, serial #84509-A, machine # 68. He had made two adjustments on the brake band when the operator turned off the power. With tools in hand, Employee #1 reached through an opening to make a third adjustment. As his hand entered the machine, his left middle finger became caught in the rotating lube pump gears and was amputated. Employee #1 was taken to Arrowhead Regional Medical Center and then transferred to Loma Linda University Medical Center. The employer was cited for a serious accident-related violation of T8CCR 3314(a), a serious non-accident related violation of T8CCR 4002(a), and a regulatory violation of T8CCR 342(a). Employee #1 later stated that the power on the machine was turned off, but that he did not wait for the gears to come to a complete stop.

Keywords: MAINTENANCE, ROTATING PARTS, AMPUTATED, FINGER, WORK RULES, CAUGHT BY, LOCKOUT, BLIND REACHING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119950004 Hospitalized injury Amputation Helpers, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close