Inspection Detail
Inspection: 119842755 - Advanced Packaging And Products/Pjh Brands
Inspection Information - Office: Los Angeles District Office
Site Address:
Advanced Packaging And Products/Pjh Brands
16131 S. Maple Ave.
Gardena, CA 90248
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2816
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 01/03/1994
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 05/23/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362010613 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 4 | 5 | |||
| Current Violations | 1 | 4 | 5 | |||
| Initial Penalty | $1,030 | $0 | $0 | $610 | $0 | $1,640 |
| Current Penalty | $1,030 | $0 | $0 | $610 | $0 | $1,640 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 5143 A05 | 01/03/1994 | 07/01/1994 | $135 | $135 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Other | 5144 C | 01/03/1994 | 02/03/1994 | $135 | $135 | $0 | - | ||
| 3. | 01003 | Other | 5144 F01 | 01/03/1994 | 02/03/1994 | $135 | $135 | $0 | - | ||
| 4. | 01004 | Other | 3383 A | 01/03/1994 | 01/17/1994 | $205 | $205 | $0 | - | ||
| 5. | 02001 | Serious | 5417 E | 01/03/1994 | 01/17/1994 | $1,030 | $1,030 | $0 | - |
Investigation Summary
On October 19, 1993, Employee #1 was in the paint mixing room at Advanced Packaging and Products Co., a paint manufacturer, dispensing toluene from a wall-mounted Morrison nozzle into an open 1 gallon plastic bucket. The toluene vapors ignited and toluene spilled out of the bucket. The flames spread to Employee #1's pants legs. His pants were made of 35 percent cotton and 65 percent polyester. Employee #1 suffered third-degree burns to both legs. The contributing factors to his injury were the use of an open bucket to transport a flammable liquid, and Employee #1's lack of flame-retardent clothing. The suspected ignition source is static electricity.
Keywords: BURN, CLOTHING, STATIC ELECTRICITY, PROTECTIVE CLOTHING, FLAMMABLE LIQUID, FLAMMABLE VAPORS, WORK RULES, FIRE, TOLUENE, LEG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119842755 | Hospitalized injury | Burn/Scald(Heat) | Mixing and blending machine operators |