Powered by GoogleTranslate

Inspection Detail

Inspection: 119839496 - Allied Signal Inc

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 119839496
Report ID: 0950641
Date Opened: 06/16/1993

Site Address:
Allied Signal Inc
850 S. Sepulveda Bl.
El Segundo, CA 90245

Mailing Address:
, , 00000

Union Status: Union

SIC:2833

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 11/19/1993

Emphasis:

Case Closed: 04/21/1995


Related Activity
Type Activity Nr Safety Health
Accident 362007239
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3383 A 11/24/1993 11/30/1993 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170158455
Event: 06/16/1993
Employee's head and neck burned by hydrochloric acid

At approximately 10:00 a.m., on June 16, 1993, Employee #1, of Allied Signal, was putting a fitting on an airline/waterline on the ground below the Genetron process plant in El Segundo, CA. A chemical reaction occurred in the hydrogen fluoride (HF) recycle flowmeter #FE-470 (micromotion), releasing hydrochloric acid that spilled on Employee #1. He was admitted to Centinella Hospital, Inglewood, CA, with chemical burns to the head and neck. Employee #1 had not been provided personal protective equipment for protection against chemical releases.

Keywords: HEAD, HYDROCHLORIC ACID, PROTECTIVE CLOTHING, PPE, HYDROGEN FLUORIDE, WORK RULES, CHEMICAL REACTION, CHEMICAL BURN, ACCIDENTAL DISCHARGE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119839496 Hospitalized injury Burn(Chemical) Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close