Inspection: 119825016 - Airgas West

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 119825016
Report ID: 0950642
Date Opened: 11/30/2000

Site Address:
Airgas West
11711 S Alameda St
Los Angeles, CA 90059

Mailing Address:
4007 Paramount Bl # 100, Lakewood, CA 90712

Union Status: NonUnion

SIC:2813

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/11/2001

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/09/2005


Related Activity
Type Activity Nr Safety Health
Accident 362613374
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $1,495 $0 $1,495
Current Penalty $0 $0 $0 $1,160 $0 $1,160
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3310 A 05/11/2001 06/13/2001 $0 $335 $0 07/16/2001 F - Formal Settlement  
2. 01002 Other 3328 A 05/11/2001 06/13/2001 $335 $335 $0 07/16/2001 F - Formal Settlement  
3. 01003 Other 5507 A 05/11/2001 06/13/2001 $600 $600 $0 07/16/2001 F - Formal Settlement  
4. 01004 Other 5507 F 05/11/2001 06/13/2001 $225 $225 $0 -  

Investigation Summary

Investigation Nr: 201054830
Event: 11/17/2000
Employee Is Burned in Explosion

At approximately 2:26 p.m. on November 17, 2000, Employee #1 had begun to fill "E" size medical oxygen cylinders using the east section of the manifold at the medical oxygen filling area. At approximately 2:00 p.m., Employee #1 shut off the oxygen pump #2 because cylinders were getting hot. While he was waiting for the cylinders to cool off, Employee #1 removed old labels from the cylinders on the bottom rack and noticed that the temperature of a cylinder was increasing instead of decreasing. Employee #1 checked the pressure on the manifold system and realized that the pressure was increasing even though the pump #2 was turned off. Then, Employee #1 tried to close the fill valve and to open the vent valve to control the pressure. There was a lot of hissing sound coming from the manifold and Employee #1 noticed the manifold pressure was reaching 3,100 p.s.i. As Employee #1 was trying to get away from the manifold system; there was an explosion. Employee #1 was on fire and kept moving away from the manifold when another employee came over to help put out the fire. Employee #1 was transported to the Martin Luther King Hospital by the paramedics and then was transferred to UCI Medical Center and hospitalized for ten to eleven days.

Keywords: BURN, OXYGEN, CYLINDER, EXPLOSION, OVERHEATED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119825016 Hospitalized injury Burn/Scald(Heat) Packaging and filling machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.