Powered by GoogleTranslate

Inspection Detail

Inspection: 119742047 - Romic Environmental Technologies

Inspection Information - Office: Foster City District Office

 

Inspection Nr: 119742047
Report ID: 0950613
Date Opened: 02/16/1995

Site Address:
Romic Environmental Technologies
2081 Bay Road
East Palo Alto, CA 94303

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2869

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/11/1995

Emphasis:

Case Closed: 05/11/2007


Related Activity
Type Activity Nr Safety Health
Accident 362301772
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 8 13
Current Violations 4 2 7 13
Initial Penalty $3,745 $100,000 $0 $1,770 $0 $105,515
Current Penalty $4,025 $100,000 $0 $1,490 $0 $105,515
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5144 F01 08/11/1995 09/13/1995 $0 $0 $0 09/07/1995 W - Empr Withdrew  
2. 01002 Other 5192 P01 08/11/1995 09/13/1995 $560 $560 $0 09/07/1995 W - Empr Withdrew  
3. 01003 Other 5157 D05 08/11/1995 08/21/1995 $280 $280 $0 09/07/1995 W - Empr Withdrew  
4. 01004 Other 5157 F 08/11/1995 09/13/1995 $185 $185 $0 09/07/1995 W - Empr Withdrew  
5. 01005 Other 5157 I03 08/11/1995 09/13/1995 $185 $185 $0 09/07/1995 W - Empr Withdrew  
6. 01006 Other 5157 E02 08/11/1995 09/13/1995 $0 $0 $0 09/07/1995 W - Empr Withdrew  
7. 01007 Other 3210 A 08/11/1995 09/13/1995 $280 $280 $0 09/07/1995 W - Empr Withdrew  
8. 01008 Serious 3270 B 08/11/1995 09/13/1995 $280 $280 $0 09/07/1995 W - Empr Withdrew  
9. 02001 Serious 5157 D03 08/11/1995 08/21/1995 $1,405 $1,405 $0 09/07/1995 W - Empr Withdrew  
10. 03001 Serious 5157 I04 08/11/1995 08/21/1995 $1,405 $1,405 $0 09/07/1995 W - Empr Withdrew  
11. 04001 Serious 5162 B 08/11/1995 08/21/1995 $935 $935 $0 09/07/1995 W - Empr Withdrew  
12. 05001 Willful 5157 K 08/11/1995 08/21/1995 $37,500 $37,500 $0 09/07/1995 W - Empr Withdrew  
13. 06001 Willful 5144 B 08/11/1995 08/16/1995 $62,500 $62,500 $0 09/07/1995 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 170727663
Event: 02/16/1995
Employee injured cleaning hazardous waste

Employee #1, employed by a hazardous waste company at an off-site rail car cleaning operation, was cleaning a railroad tank car containing sludge with volatile organics and heavy metals (hazardous waste). A coworker, a confined space attendant/superintendent, was on the platform. Another coworker was on the ground monitoring the equipment. Employee #1 was using a Willson PD full face respirator with a five minute bottle. He lost air supply and was pulled out by the superintendent. Employee #1 suffered injury to the central nervous system due to hypoxia. The respirator's air supply was improperly operated and the coupling, which failed, had been taped.

Keywords: ASPHYXIATED, CONFINED SPACE, INADEQUATE MAINT, RAILROAD TANK CAR, WORK RULES, CLEANING, SCBA, HAZARDOUS WASTE, RESPIRATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119742047 Non Hospitalized injury Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close