Powered by GoogleTranslate

Inspection Detail

Inspection: 119706679 - American Xtal Technology

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 119706679
Report ID: 0950614
Date Opened: 08/01/1995

Site Address:
American Xtal Technology
6780 Sierra Ct., Suite #I
Dublin, CA 94568

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3674

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/07/1995

Emphasis:

Case Closed: 07/01/1996


Related Activity
Type Activity Nr Safety Health
Accident 361620974
Accident 362139420
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 4 1 5
Initial Penalty $2,500 $0 $0 $125 $0 $2,625
Current Penalty $2,500 $0 $0 $125 $0 $2,625
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5144 D02 09/20/1995 10/20/1995 $125 $125 $0 -  
2. 02001 Serious 23500011 09/20/1995 09/30/1995 $625 $625 $0 -  
3. 03001 Serious 3235 E 09/20/1995 09/30/1995 $625 $625 $0 -  
4. 04001 Serious 3272 B 09/20/1995 09/30/1995 $625 $625 $0 -  
5. 05001 Serious 5474 C 09/20/1995 09/30/1995 $625 $625 $0 -  

Investigation Summary

Investigation Nr: 170702690
Event: 06/19/1995
Employee burns arm in hydrogen fluroide bath

Employee #1, of American Xtal Technology, was about to wash quartz tubes at a hydrogen fluoride station. She put on one pair of gloves when she was supposed to put on two, and then quickly dipped her fingers in and out of a hydrogen fluoride bath. Employee #1 attempted to remove the gloves, contaminating her right forearm in the process. Coworkers came to decontaminate her. They applied a special ointment and took her to the emergency clinic, where she received treatment. Employee #1, who had been trained that morning, suffered first- and second-degree burns. Because of her chemical burn, Employee #1 quit her job. There were no accident-related violations.

Keywords: BURN, PPE, GLOVE, HYDROGEN FLUORIDE, WORK RULES, FOREARM, INEXPERIENCE, CHEMICAL BURN, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119706679 Non Hospitalized injury Burn(Chemical) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close