Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 119689651 - Acme & Sons Sanitation

Inspection Information - Office: Ca Fremont District Office

Nr: 119689651Report ID: 0950612Open Date: 09/06/2000

Acme & Sons Sanitation
3408 Hillcap Ave
San Jose, CA 95136
Union Status: NonUnion
SIC: 2842/Specialty Cleaning, Polishing, and Sanitation Preparations

Inspection Type:Accident
Scope:Complete Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:01/17/2001
Close Case:10/30/2001

Related Activity:TypeIDSafetyHealth
 Accident101798262    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 3 12 15
Current Violations 3 12 15
Initial Penalty $35,125 $0 $0 $3,305 $0 $38,430
Current Penalty $35,125 $0 $0 $3,305 $0 $38,430
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Other 342 A 02/16/2001 02/22/2001 $375 $375 $0 -
  2. 01002 Other 3664 A 02/16/2001 03/05/2001 $185 $185 $0 -
  3. 01003 Other 3660 A 02/16/2001 03/05/2001 $185 $185 $0 -
  4. 01004 Other 3661 C 02/16/2001 03/05/2001 $185 $185 $0 -
  5. 01005 Other 3668 B01 02/16/2001 03/05/2001 $185 $185 $0 -
  6. 01006 Other 5144 C01 02/16/2001 03/05/2001 $185 $185 $0 -
  7. 01007 Other 3314 G 02/16/2001 03/05/2001 $560 $560 $0 -
  8. 01008 Other 461 C 02/16/2001 03/05/2001 $375 $375 $0 -
  9. 01009 Other 14305 C 02/16/2001 03/05/2001 $325 $325 $0 -
  10. 01010 Other 23400022 A 02/16/2001 03/05/2001 $185 $185 $0 -
  11. 01011 Other 4650 H 02/16/2001 03/05/2001 $185 $185 $0 -
  12. 01012 Other 3203 B01 02/16/2001 03/21/2001 $375 $375 $0 -
  13. 02001 Serious 5162 A 02/16/2001 03/05/2001 $3,375 $3,375 $0 -
  14. 03001 Serious 23400023 02/16/2001 03/05/2001 $6,750 $6,750 $0 -
  15. 04001 Serious 23200007 B 02/16/2001 03/05/2001 $25,000 $25,000 $0 -

Accident Investigation Summary
Summary Nr: 202312633Event: 08/10/2000Electric Shock - Contact With Energized Parts Thru Rule
An employee was using a plastic measuring tape to measure a circuit breaker bracket inside an energized panelboard. The metal hook on the measuring tape contact a busbar and caused an electrical fault. The ensuing electric arc burned the employee on his face and body. He was hospitalized for his injuries.
Keywords: burn, electric arc, e gi iv, electrical, measuring device, ppe, panelboard, electrical work, lockout, electrical fault
Inspection Degree Nature Occupation
1 119689651 Hospitalized injury Burn/Scald(Heat) Supervisors, mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.