Powered by GoogleTranslate

Inspection Detail

Inspection: 119624179 - Air Comp Llc

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 119624179
Report ID: 0950615
Date Opened: 07/19/2003

Site Address:
Air Comp Llc
Nabors Rig #476
Geyserville, CA 95541

Mailing Address:
37 South University Street, Healdsburg, CA 95448

Union Status: NonUnion

SIC:4961

NAICS: 221330/Steam and Air-Conditioning Supply


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/31/2003

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/24/2006


Related Activity
Type Activity Nr Safety Health
Accident 361600174
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $3,915 $0 $0 $410 $0 $4,325
Current Penalty $3,915 $0 $0 $410 $0 $4,325
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 B 12/31/2003 01/06/2004 $410 $410 $0 -  
2. 02001 Serious 23950083 A03 12/31/2003 01/06/2004 $2,475 $2,475 $0 -  
3. 03001 Serious 3328 A 12/31/2003 01/06/2004 $1,440 $1,440 $0 -  

Investigation Summary

Investigation Nr: 170838775
Event: 07/19/2003
Employee dies in explosion

At approximately 3:15 p.m. on July 19, 2003, Employee #1, a new employee, was operating trailer-mounted mobile equipment to supply compressed air to a steam well drilling rig. The equipment was manufactured by Air Comp, LLC, an Allis-Chalmers/M-1 Company. As he attempted to divert oil and water contaminated air from a filter chamber into a 350-gallon disposal holding tank, provided by Cal-Pine, the disposal tank became pressurized and exploded. Large parts of the tank became airborne, striking Employee #1. He was hospitalized and pronounced dead due to injuries sustained. A detailed investigation revealed that two venting plugs, located on the tank, were not removed, causing pressurization of the tank and eventual explosion.

Keywords: PRESSURE VESSEL, VENTING, EXPLOSION, STRUCK BY, TANK, PRESSURE RELEASE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119624179 Fatality Amputation Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close