Powered by GoogleTranslate

Inspection Detail

Inspection: 119545713 - Kpg Construction, Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 119545713
Report ID: 0352410
Date Opened: 02/24/2000

Site Address:
Kpg Construction, Inc.
27268 Riverside Drive
Salisbury, MD 21801

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1751

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/01/2000

Emphasis:

Case Closed: 06/01/2000


Related Activity
Type Activity Nr Safety Health
Accident 100966423
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 1 7
Current Violations 6 1 7
Initial Penalty $8,750 $0 $0 $0 $0 $8,750
Current Penalty $1,200 $0 $0 $0 $0 $1,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260451 C02 I 04/17/2000 04/20/2000 $200 $1,375 $0 I - Informal Settlement  
2. 01002 Serious 19260451 G01 04/17/2000 04/20/2000 $200 $1,500 $0 I - Informal Settlement  
3. 01003 Serious 19260452 K04 04/17/2000 04/20/2000 $200 $1,500 $0 I - Informal Settlement  
4. 01004 Serious 19260454 A 04/17/2000 05/20/2000 $200 $1,500 $0 I - Informal Settlement  
5. 01005 Serious 19260454 B 04/17/2000 05/20/2000 $200 $1,500 $0 I - Informal Settlement  
6. 02001 Serious 19261053 B05 I 04/17/2000 04/20/2000 $200 $1,375 $0 I - Informal Settlement  
7. 03001 Other 19260451 B02 I 04/17/2000 04/20/2000 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200965184
Event: 02/24/2000
Employee Injured In Fall

A ladder jack scaffold had been constructed on the rear side of the dwelling in order to install a dormer for the existing dwelling. The supporting ladders were not secured to prevent displacement and the feet of the ladder on the left (if facing the system) were not in place (they were in the unused position). This ladder was not placed on an adequate foundation (it was positioned on soft soil). The ladders were placed at an improper pitch and due to their lack of length the top portion of the ladder rested upon the fascia of the structure. The employees on the scaffold were not protected against falls. The construction of the dormer had progressed to the point where J-channel needed to be installed around the dormer window. Employee #1 was unclear regarding the manner of installation of the J-channel. The job foreman ascended the left supporting ladder of the system. Employee #1 ascended behind him once he was off of the ladder and onto the scaffold. Both persons were on the scaffold and were standing side by side discussing installation of this channel. Their combined weight of approximately 300 pounds caused the ladder feet to slowly sink into the soft earth. Eventually the upper portion of the ladder no longer contacted the fascia, causing the ladder support to fall toward the building wall. This resulted in an abrupt shifting of the platform and Employee #1 fell backwards approximately 13-ft-9-in. to the ground. The foreman grabbed onto the roof while another employee leaning out of the dormer window and was able to hold onto the foreman preventing them from falling. Employee #1 was hospitalized.

Keywords: FRACTURE, LADDER JACK SCAFFOLD, UNSTABLE SURFACE, FALL, UNSTABLE SOIL, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119545713 Hospitalized injury Fracture Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close