Powered by GoogleTranslate

Inspection Detail

Inspection: 116310905 - Teccor Electronics, Inc.

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 116310905
Report ID: 0626300
Date Opened: 04/11/1995

Site Address:
Teccor Electronics, Inc.
1801 Hurd Drive
Irving, TX 75038

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3674

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/12/1995

Emphasis:

Case Closed: 01/16/1997


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 1 7
Current Violations 6 1 7
Initial Penalty $42,000 $70,000 $0 $0 $0 $112,000
Current Penalty $0 $0 $0 $1,500 $27,000 $28,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100120 Q02 II 10/05/1995 10/25/1995 $500 $7,000 $0 10/18/1995 F - Formal Settlement  
2. 01002A Other 19100120 Q02 III 10/05/1995 10/25/1995 $0 $7,000 $0 10/18/1995 F - Formal Settlement  
3. 01002B Other 19100120 Q02 IX 10/05/1995 10/25/1995 $0 $0 $0 10/18/1995 F - Formal Settlement  
4. 01003 Other 19100120 Q02 X 10/05/1995 10/25/1995 $0 $7,000 $0 10/18/1995 F - Formal Settlement  
5. 01004 Other 19100120 Q08 II 10/05/1995 10/18/1995 $0 $7,000 $0 10/18/1995 F - Formal Settlement  
6. 01005A Other 19100134 F02 II 10/05/1995 10/18/1995 $500 $7,000 $0 10/18/1995 F - Formal Settlement  
7. 01005B Other 19100134 F02 IV 10/05/1995 10/18/1995 $0 $0 $0 10/18/1995 F - Formal Settlement  
8. 01006 Other 19101200 H03 III 10/05/1995 10/18/1995 $500 $7,000 $0 10/18/1995 F - Formal Settlement  
9. 02001 Unclass 5A0001 10/05/1995 10/18/1995 $27,000 $70,000 $0 10/18/1995 F - Formal Settlement  

Investigation Summary

Investigation Nr: 170087589
Event: 04/11/1995
Three employees overexposed to nitrogen dioxide

Employees #1 and #2 were working in a cleanroom at a semiconductor manufacturer. A concentrated mixture of nitric, hydrofluoric, and acetic acids was being used to etch on silicon wafers in an enclosed, ventilated machine. The acid was also being recirculated by a pump outside the machine. The faulty pump was leaking into a containment box, which eventually overflowed onto a floor littered with waste silicon wafers. It has not been determined how much acid overflowed. The acid mixture reacted with the waste wafer chips, creating a yellowish brown cloud of nitrogen dioxide. The employees summoned their supervisors, who brought them back to the room for about five minutes to determine the cloud's origin. No one was wearing any respiratory protection. Employee #3 entered from a door directly in front of the cloud. She gasped immediately and began choking. Employees #1, #2, and #3 were taken to the hospital and treated overnight for inhalation of corrosive gas. They continue to have respiratory difficulties.

Keywords: LEAK, RESPIRATORY, WORK RULES, INHALATION, EQUIPMENT FAILURE, CHEMICAL REACTION, CORROSIVE, POISONING, TOXIC FUMES, RESPIRATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 116310905 Hospitalized injury Poisoning(Systemic) Electrical and electronic technicians
2 116310905 Hospitalized injury Poisoning(Systemic) Electrical and electronic technicians
3 116310905 Hospitalized injury Poisoning(Systemic) Electrical and electronic technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close