Powered by GoogleTranslate

Inspection Detail

Inspection: 115777484 - Fugua Homes Inc

Inspection Information - Office: Or-E-Salem 1054100

 

Inspection Nr: 115777484
Report ID: 1054118
Date Opened: 04/21/1994

Site Address:
Fugua Homes Inc
20495 Murray Rd
Bend, OR 97701

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2451

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/24/1994

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/21/2010


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $10,540 $0 $0 $250 $0 $10,790
Current Penalty $5,540 $0 $0 $250 $0 $5,790
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19101200 G08 09/08/1994 06/10/1994 $240 $240 $0 -  
2. 01002 Serious 19101200 H 09/08/1994 09/11/1994 $300 $300 $0 -  
3. 01003 Serious 740003001 09/08/1994 09/11/1994 $5,000 $10,000 $0 09/19/1994 J - ALJ Decision  
4. 02004 Other 701005201 09/08/1994 09/11/1994 $250 $250 $0 09/19/1994 J - ALJ Decision  

Investigation Summary

Investigation Nr: 789792
Event: 04/21/1994
Employee's head punctured by air nail gun

At around 4:20 p.m. on April 15, 1994, Employee #1 was at a manufactured home plant in Bend, OR. He attempted to step down and walk beside a coworker who was standing on a 5 ft stepladder installing sheet rock on a header with a Dual Fast pneumatic nail gun. When the coworker finished nailing the header, he lowered the nail gun with his finger on the trigger and contacted the head of Employee #1, who was stooped over. The safety trigger release on the nail gun depressed and a 1 1/2 inch nail entered Employee #1's head. Employee #1 was transported by ambulance to the St. Charles Hospital in Bend and was released after two nights' stay.

Keywords: PORTABLE POWER TOOL, HEAD, AIR SPRING, INSTALLING, NAIL, HAND TOOL, INATTENTION, PUNCTURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 115777484 Hospitalized injury Puncture Production helpers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.