Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 115739468 - Forslund Construction Inc

Inspection Information - Office: Or Eugene

Nr: 115739468Report ID: 1054114Open Date: 12/03/1991

Forslund Construction Inc
Catherine Way
Albany, OR 97321
Union Status: NonUnion
SIC: 1611/Highway and Street Construction, Except Elevated Highways
Mailing: 3001 Sw Ferry, Alabany, OR 97321

Inspection Type:Accident
Scope:Complete Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:03/31/1992
Planning Guide: Safety-Construction Close Case:10/15/1992

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $2,500 $0 $0 $0 $0 $2,500
Current Penalty $1,750 $0 $0 $0 $0 $1,750
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19260550 A15 II 04/10/1992 12/03/1991 $0 $0 $0 04/16/1992 L - State Settlement
  2. 91991 Serious 19260550 A15 II 04/10/1992 12/03/1991 $1,750 $2,500 $0 L - State Settlement

Accident Investigation Summary
Summary Nr: 170088454Event: 11/25/1991Electric Shock - Contact With Overhead Line Thru Boom
AN EMPLOYEE WAS IN THE CONTROL CAB OF AN 80-TON MOBILE, RUBBER-TIRED CRANE. A COWORKER WAS AT THE CONTROLS FOR THE OPERATION OF THE CRANE CARRIER. THE COWORKER WAS MOVING THE CRANE WHILE THE BOOM WAS IN A RAISED POSITION. HE BACKED THE CRANE INTO A 12-KILOVOLT OVERHEAD POWER LINE, WHICH CONTACTED A WIRE ROPE ON THE BACK SIDE OF THE BOOM. THE CRANE'S TIRES IGNITED, SO THE EMPLOYEE IN THE CONTROL CAB JUMPED TO THE GROUND AND BEGAN TO RUN AWAY FROM THE CRANE. UNFORTUNATELY, HE RAN INTO THE SPREADER BAR AND STRAP HANGING FROM THE CRANE'S LOAD LINE. THE EMPLOYEE RECEIVED AN ELECTRIC SHOCK. HE WAS HOSPITALIZED FOR HIS INJURIES.
Keywords: overhead power line, electrical, boom, crane boom, e gi ia, electric shock, load line, crane
Inspection Degree Nature Occupation
1 115739468 Hospitalized injury Electric Shock Crane and tower operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.