Powered by GoogleTranslate

Inspection Detail

Inspection: 115047185 - Star Building Systems

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 115047185
Report ID: 0751910
Date Opened: 07/06/1992

Site Address:
Star Building Systems
101 W. South Street
Monticello, IA 52310

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3441

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/08/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/13/1993


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 1 8
Current Violations 7 1 8
Initial Penalty $16,500 $0 $0 $0 $0 $16,500
Current Penalty $9,000 $0 $0 $0 $0 $9,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100106 E02 IIB2 07/29/1992 09/14/1992 $1,500 $2,625 $0 I - Informal Settlement  
2. 01002 Serious 19100147 C01 07/29/1992 09/14/1992 $1,500 $2,625 $0 I - Informal Settlement  
3. 01003 Serious 19100147 D03 07/29/1992 09/14/1992 $1,500 $2,625 $0 I - Informal Settlement  
4. 01004 Serious 19100212 A03 II 07/29/1992 09/14/1992 $1,500 $2,625 $0 I - Informal Settlement  
5. 01005 Serious 19100217 C02 IA 07/29/1992 09/14/1992 $1,500 $2,625 $0 I - Informal Settlement  
6. 01006 Serious 19100219 F03 07/29/1992 09/14/1992 $750 $1,500 $0 I - Informal Settlement  
7. 01007 Serious 19100252 B02 III 07/29/1992 09/14/1992 $750 $1,875 $0 I - Informal Settlement  
8. 02001 Other 19100217 E01 I 07/29/1992 09/14/1992 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 828251
Event: 07/06/1992
Employee's fingertip amputated by hold-down

Employee #1 was operating a hydraulic shear when his right ring finger slipped under the guard and the ring guard for the hold-down. As the machine cycled, the hold-down came down and pinched off the end of his finger. The employee's finger slid under the hold-down through an opening created because the guard was not adjusted within 1/4 inch of the material.

Keywords: SHEARING MACHINE, AMPUTATED, INADEQUATE MAINT, FINGER, WORK RULES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 115047185 Non Hospitalized injury Amputation Misc. metal,plastic,stone&glass-working mach. op's
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close