Powered by GoogleTranslate

Inspection Detail

Inspection: 114619364 - S E Inc

Inspection Information - Office: Wyoming Department Of Workforce Services - Osha Division

 

Inspection Nr: 114619364
Report ID: 0855610
Date Opened: 10/11/1993

Site Address:
S E Inc
County Road, 30, Gebo
Kirby, WY 82430

Mailing Address:
P.O. Box 165, Deaver, WY 82421

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/13/1993

Planning Guide: Safety-Manufacturing

Emphasis: L:Constr

Case Closed: 01/18/1994


Related Activity
Type Activity Nr Safety Health
Accident 360790315
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $3,000 $0 $0 $0 $0 $3,000
Current Penalty $1,200 $0 $0 $0 $0 $1,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious CO140007 B02D 11/01/1993 12/07/1993 $600 $1,500 $0 I - Informal Settlement  
2. 01002 Serious CO140007 B02E 11/01/1993 12/07/1993 $600 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 756429
Event: 10/08/1993
Employee Dies in Fall from Aerial Lift

A power line worker was in an aerial lift 12.2 meters above the ground, clipping in a transmission line conductor wire at a 13-degree-angle structure. The employee was not using the rigging designed for clipping an angle structure. Instead of using two conductor grips and a choker, he was using a crane horsehead to push the conductor to the appropriate 13-degree angle. The conductor slipped off the horsehead and struck the employee. The impact threw him out of the aerial lift platform. He died from injuries sustained in the fall. The power line worker was not using fall-arrest equipment, and he was not standing on the floor of the platform.

Keywords: WORK RULES, ELEC UTILITY WORK, ELECTRIC CONDUCTOR, FALL, FALL PROTECTION, FLYING OBJECT, TRANSMISSION TOWER, TENSION RELEASE, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 114619364 Fatality Other Electrical power installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close