Inspection: 113764476 - New Jersey Steel Corp.

Inspection Information - Office: Avenel Area Office

 

Inspection Nr: 113764476
Report ID: 0213400
Date Opened: 11/09/1995

Site Address:
New Jersey Steel Corp.
11 North Crossman Rd.
Sayreville, NJ 08871

Mailing Address:
P.O. Box 96, Sayreville, NJ 08871

Union Status: NonUnion

SIC:3312

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/08/1996

Emphasis:

Case Closed: 05/22/1996


Related Activity
Type Activity Nr Safety Health
Accident 361990252

Investigation Summary

Investigation Nr: 170401277
Event: 11/09/1995
Employee killed when roof collapsed under his weight

At approximately 10:40 a.m. on November 9, 1995, Employee #1 walked on a catwalk from the lime silos to the furnace bay roof, where he climbed over a 42 inch guardrail onto a support truss. He lowered himself 8 feet, and then walked 8 feet to the roof's edge. Employee #1 jumped 10 feet to the roof of the scrap bay building. The roof could not support his weight and he fell through it 27 feet, landing atop a 28 feet high building that was inside the scrap bay building. Employee #1 was killed.

Keywords: ROOF COLLAPSE, ROOF, WORK RULES, FALL, FALL PROTECTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 113764476 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.