Inspection Detail
Inspection Information - Office: North Boston | ||||
---|---|---|---|---|
Nr: 113547533 | Report ID: 0134000 | Open Date: 10/25/2001 | ||
J. Tropeano, Inc. | ||||
Harkaway Road North Andover, MA 01845 | Union Status: NonUnion | |||
SIC: 1623/Water, Sewer, Pipeline, and Communications and Power Line Construction | ||||
Mailing: 1780 Osgood Street, North Andover, MA 01845 | ||||
Inspection Type: | Planned | |||
Scope: | Complete | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 12/20/2001 | |
Emphasis: | N:Trench | Close Case: | 01/13/2003 | |
Related Activity: | Type | ID | Safety | Health |
Referral | 901876946 | Yes |
Violation Summary | ||||||
---|---|---|---|---|---|---|
Serious | Willful | Repeat | Other | Unclass | Total | |
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $2,000 | $14,000 | $0 | $0 | $0 | $16,000 |
Current Penalty | $1,400 | $9,800 | $0 | $0 | $0 | $11,200 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
Violation Items | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
1. | 01001 | Serious | 19260651 J02 | 01/07/2002 | 01/10/2002 | $1,400 | $2,000 | $0 | I - Informal Settlement | ||
2. | 02001 | Willful | 19260652 A01 | 01/07/2002 | 01/10/2002 | $9,800 | $14,000 | $0 | I - Informal Settlement |
Accident Investigation Summary | ||||||
Summary Nr: 656330 | Event: 10/25/2001 | Employee Injured In Trench Collapse | ||||
Employee #1 was working in an unprotected trench that was 6 ft to 7 ft deep. The sidewall collapsed onto Employee #1 resulting in a broken hip and pelvis. Employee #1 was hospitalized. | ||||||
Keywords: fracture, collapse, construction, trench, pelvis, hip, unguarded | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 113547533 | Hospitalized injury | Fracture | Construction laborers |