Inspection Detail
Inspection: 113325435 - Industrial Contract Services, Inc.
Inspection Information - Office: Bismarck Area Office
Site Address:
Industrial Contract Services, Inc.
West Of Highway #81 Nw
Grand Forks, ND 58206
Mailing Address:
P.O. Box 5159, Grand Forks, ND 58206
Union Status: NonUnion
SIC:1629
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 11/29/1995
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/14/1996
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360454854 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
Current Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 02/09/1996 | 02/22/1996 | $2,500 | $2,500 | $0 | - | ||
2. | 01002A | Serious | 19260021 B05 | 02/09/1996 | 03/12/1996 | $2,500 | $2,500 | $0 | - | ||
3. | 01002B | Serious | 19260021 B06 I | 02/09/1996 | 03/12/1996 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1 entered a concrete manhole structure carrying a propane gas-fired blowtorch. While he was operating the torch, the propane container toppled over and caused the regulator to break away from the main valve assembly. The released propane gas vapors ignited, causing a fire. Employee #1 died of asphyxia.
Keywords: ASPHYXIATED, FLAMMABLE VAPORS, FIRE, CONSTRUCTION, INHALATION, PROPANE TORCH, GAS LEAK, MANHOLE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 113325435 | Fatality | Asphyxia | Occupation not reported |