Inspection Detail
Inspection: 113212856 - Precision Metal Products, Inc.
Inspection Information - Office: Bridgeport Area Office
Site Address:
Precision Metal Products, Inc.
307 Pepe Farms Road
Milford, CT 06460
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3559
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/09/1996
Emphasis:
Case Closed: 01/02/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 903122455 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $3,850 | $0 | $0 | $0 | $0 | $3,850 |
| Current Penalty | $1,920 | $0 | $0 | $0 | $0 | $1,920 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100217 B07 VC | 12/11/1996 | 12/16/1996 | $960 | $1,925 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100217 E01 II | 12/11/1996 | 01/17/1997 | $960 | $1,925 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 2:30 a.m. on September 19, 1996, Employee #1 was operating a Minster mechanical power press when the chain drive broke, causing the press to operate in a continuous mode. Employee #1 was reaching into the point of operation to remove a part when the machine cycled and partially amputated a finger. The press did not have an anti-repeat feature installed.
Keywords: AMPUTATED, POWER PRESS, FINGER, WORK RULES, EQUIPMENT FAILURE, POINT OF OPERATION, PRESS OPERATOR, PRESS
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 113212856 | Hospitalized injury | Amputation | Occupation not reported |