Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1126005.015 - 128645 - Spx Transformer Solutions, Inc.

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 1126005.015
Report ID: 0453710
Date Opened: 12/01/2015

Site Address:
128645 - Spx Transformer Solutions, Inc.
2701 Us Highway 117 South
Goldsboro, NC 27530

Mailing Address:
2701 Us Highway 117 South, Goldsboro, NC 27530

Union Status: Union

SIC:3612

NAICS: 335311/ Power, Distribution, and Specialty Transformer Manufacturing


Inspection Type: Fat/Cat

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/25/2016

Emphasis: N:Chrome6

Case Closed: 10/31/2017


Related Activity
Type Activity Nr Safety Health
Accident 1042776
Inspection 1406901 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 5 5
Initial Penalty $43,000 $0 $0 $0 $0 $43,000
Current Penalty $17,500 $0 $0 $0 $0 $17,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100146 D03 IV 05/25/2016 05/31/2016 $3,500 $7,000 $0 07/08/2016 C - Contested  
2. 01002 Serious 19100146 D05 I 05/25/2016 05/31/2016 $7,000 $7,000 $0 07/08/2016 C - Contested  
3. 01003 Serious 19100146 D05 II 05/25/2016 05/31/2016 $0 $7,000 $0 07/08/2016 C - Contested  
4. 01004 Serious 19100146 D09 05/25/2016 05/31/2016 $0 $4,000 $0 07/08/2016 C - Contested Citation has been deleted.
5. 01005 Serious 19100146 E01 05/25/2016 05/31/2016 $7,000 $7,000 $0 07/08/2016 C - Contested  
6. 01006 Serious 19100146 G01 05/25/2016 05/31/2016 $0 $4,000 $0 07/08/2016 C - Contested Citation has been deleted.
7. 01007 Serious 19100146 H02 05/25/2016 05/31/2016 $0 $7,000 $0 07/08/2016 C - Contested  

Investigation Summary

Investigation Nr: 83095.015
Event: 11/30/2015
Two employees enter oxygen deficient environment and are kil

On November, 30, 2015, employee #1 entered a large transformer, top cover removed, that had previously been filled with nitrogen. Employee #1 fell unconsious. Employee #2 entered to retrieve Employee #1 and also fell unconscious. Employee #3 followed and also fell unconscious. Employees #1 and #2 died. Employee #3 was hospitalized.

Keywords: Asphyxiated, Nitrogen

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1126005.015 33 M Fatality Occupation not reported
2 1126005.015 51 M Fatality Occupation not reported
3 1126005.015 40 M Hospitalized injury Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.