Powered by GoogleTranslate

Inspection Detail

Inspection: 112532056 - Battelle Memorial Institute

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 112532056
Report ID: 0522500
Date Opened: 08/12/2002

Site Address:
Battelle Memorial Institute
1425 Plain City-Georgesville Road
West Jefferson, OH 43162

Mailing Address:
505 King Avenue, Rm. A173a, Columbus, OH 43201

Union Status: NonUnion

SIC:8731

NAICS: 541710/ Research and Development in the Physical, Engineering, and Life Sciences


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 11/07/2002

Emphasis: L:Tempserv

Case Closed: 01/13/2003


Related Activity
Type Activity Nr Safety Health
Referral 200751261 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 7 7
Initial Penalty $44,100 $0 $0 $0 $0 $44,100
Current Penalty $28,665 $0 $0 $0 $0 $28,665
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 A 11/20/2002 12/23/2002 $4,778 $6,300 $0 I - Informal Settlement  
2. 01002 Serious 19101450 E03 I 11/20/2002 12/23/2002 $4,778 $6,300 $0 I - Informal Settlement  
3. 01003 Serious 19101450 E03 II 11/20/2002 12/23/2002 $4,778 $6,300 $0 I - Informal Settlement  
4. 01004 Serious 19101450 E03 VIIID 11/20/2002 12/23/2002 $4,778 $6,300 $0 I - Informal Settlement  
5. 01005 Serious 19101450 E04 11/20/2002 12/23/2002 $4,778 $6,300 $0 I - Informal Settlement  
6. 01006 Serious 19101450 F04 IB 11/20/2002 12/23/2002 $4,778 $6,300 $0 I - Informal Settlement  
7. 01007 Serious 19101450 F04 IC 11/20/2002 12/23/2002 $0 $6,300 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200754570
Event: 08/11/2002
Two Employees Are Burned When Chemical Mixture Explodes

At approximately 3:00 p.m. on August 11, 2002, Employees #1 and #2 were transferring a highly energetic mixture of aluminum flake and ammonium perchlorate when the mixture ignited and exploded. Both employees sustained serious burns and were hospitalized.

Keywords: BURN, ALUMINUM DUST, PPE, EXPLOSIVE MIXING, WORK RULES, FIRE, EXPLOSION, CHEMICAL REACTION, STRUCK BY, COMBUSTIBLE DUST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112532056 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 112532056 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.