Powered by GoogleTranslate

Inspection Detail

Inspection: 112130299 - Western Tube & Conduit Corp

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 112130299
Report ID: 0950635
Date Opened: 05/24/1995

Site Address:
Western Tube & Conduit Corp
2001 E Dominguez St
Long Beach, CA 90801

Mailing Address:
2001 E Dominguez St, Long Beach, CA 90801

Union Status: Union

SIC:3317

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/10/1995

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/15/1995


Related Activity
Type Activity Nr Safety Health
Accident 362025074
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $11,500 $0 $0 $450 $0 $11,950
Current Penalty $11,500 $0 $0 $450 $0 $11,950
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A04 08/16/1995 09/13/1995 $450 $450 $0 -  
2. 02001 Serious 3203 A02 08/16/1995 09/03/1995 $1,500 $1,500 $0 -  
3. 03001 Serious 3203 A07 08/16/1995 09/03/1995 $5,000 $5,000 $0 -  
4. 04001 Serious 3328 A 08/16/1995 09/03/1995 $5,000 $5,000 $0 -  

Investigation Summary

Investigation Nr: 170891923
Event: 05/17/1995
Employee injured when pinned by 1-ton coil of metal

At approximately 11:00 p.m. on May 17, 1995, Employee #1 was working on #3 mill-end weld station. He placed a 5 in. wide, 2,644 lb strand of galvanized 0.076 in. strip metal, used to make a 1 1/4 in. square tube, on the #3 mill coil rack. The total width of the coil bundles was about 3 ft 4 in., whereas the length of the #3 coil rack was 2 ft 10 in. As a result, the last coil hung over the coil rack. Employee #1 was standing in front of the coil bundles while cutting the bands that held the bundles together. When he cut the band from the last bundle, it was displaced due to the overhang. The coil struck Employee #1 on the chest, stomach, and thigh and pinned him against the west end of the coil rack. He was transported to Harbor UCLA Medical Center.

Keywords: UNSECURED, PINNED, WORK RULES, STRUCK BY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112130299 Hospitalized injury Other Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.