Powered by GoogleTranslate

Inspection Detail

Inspection: 112129382 - International Catalyst

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 112129382
Report ID: 0950635
Date Opened: 05/09/1995

Site Address:
International Catalyst
1660 W Anaheim St
Wilmington, CA 90748

Mailing Address:
1044 E Del Amo Blvd, Carson, CA 90746

Union Status: NonUnion

SIC:7699

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/15/1995

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 09/01/2010


Related Activity
Type Activity Nr Safety Health
Accident 362021263
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 3 3
Initial Penalty $10,000 $0 $0 $1,125 $0 $11,125
Current Penalty $0 $0 $0 $1,215 $0 $1,215
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 B01 06/16/1995 07/17/1995 $375 $375 $0 07/05/1995 F - Formal Settlement  
2. 01002 Other 3382 A 06/16/1995 07/14/1996 $280 $750 $0 07/05/1995 F - Formal Settlement  
3. 02001 Other 3384 A 06/16/1995 07/04/1996 $560 $5,000 $0 07/05/1995 F - Formal Settlement  
4. 03001 Serious 3203 A02 06/16/1995 07/04/1995 $0 $5,000 $0 07/05/1995 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 170891774
Event: 02/04/1995
Employee burned by regenerator catalyst

On February 3, 1995, Employee #1 and a coworker were working on the vacuum extraction of a catalyst from the unit 152 regenerator. They were on the fourth level deck. The regenerator manway door had been opened, showing a high catalyst bank sloping from the doorway back to the regenerator. The vacuum hose was inserted into the regenerator and extraction started. On February 4, 1995, extraction from the manway on the fourth level continued. Around 4:30 p.m., the employees briefly heard a loud sound and saw a momentary bright red glow that left white dusty catalyst powder sprayed all over. Employee #1 and his coworker had just taken off their thermal mittens and consequently suffered severe hand burns and some neck burns. Employee #1 was taken to Kaiser and then Torrance Memorial Hospital. The cause of the accident may be traced to Employee #1's injecting air from the bottom of the regenerator; firebricks falling onto the catalyst; or the vacuum extraction regenerator catalyst level suddenly folding back, giving rise to the catalyst cloud.

Keywords: GLOVE, WORK RULES, CHEMICAL BURN, NECK, POWDER, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112129382 Hospitalized injury Burn/Scald(Heat) Not specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.