Powered by GoogleTranslate

Inspection Detail

Inspection: 112104724 - Maxwell Laboratories

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 112104724
Report ID: 0950632
Date Opened: 05/11/1992

Site Address:
Maxwell Laboratories
8888 Balboa Ave.
San Diego, CA 92123

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3399

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/11/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/31/1994


Related Activity
Type Activity Nr Safety Health
Accident 361367576

Investigation Summary

Investigation Nr: 170359897
Event: 05/08/1992
BURN - ELECTRICAL FAULT IN TEST EQUIPMENT

An employee was performing a test on a capacitor. The meter had not been isolated in accordance with the employer's engineering department's recommendations. The test instrument he was using failed, burning the employee. He was hospitalized for his injuries.

Keywords: BURN, E GI II, ELECTRIC ARC, ELECTRICAL, ELECTRICAL TESTING, TEST EQUIPMENT, ELECTRICAL FAULT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112104724 Hospitalized injury Burn(Chemical) Electronic repairers, communica. & indus. equip.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.