Powered by GoogleTranslate

Inspection Detail

Inspection: 112090543 - Ecology Auto Wrecking

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 112090543
Report ID: 0950635
Date Opened: 04/21/1992

Site Address:
Ecology Auto Wrecking
1600 Eubank Street
Wilmington, CA 90744

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5093

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/24/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/11/1994


Related Activity
Type Activity Nr Safety Health
Accident 361324825
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 3 5
Current Violations
Initial Penalty $4,000 $0 $0 $0 $0 $4,000
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A03 06/24/1992 07/10/1992 $0 $0 $0 07/30/1992 J - ALJ Decision Citation has been deleted.
2. 01002 Other 3203 A04 06/24/1992 07/10/1992 $0 $0 $0 07/30/1992 J - ALJ Decision Citation has been deleted.
3. 01003 Other 3203 A07 C 06/24/1992 07/10/1992 $0 $0 $0 07/30/1992 J - ALJ Decision Citation has been deleted.
4. 02001 Serious 5432 A 06/24/1992 07/10/1992 $2,000 $2,000 $0 07/30/1992 J - ALJ Decision Citation has been deleted.
5. 03001 Serious 5433 C 06/24/1992 07/10/1992 $2,000 $2,000 $0 07/30/1992 J - ALJ Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 170187967
Event: 03/30/1992
Employees burned by igniting gasoline vapors

At about 11:00 a.m. on March 30, 1992, Employees #1, #2, and #3, of Ecology Auto Wrecking, were burned when gasoline fumes ignited and exploded. Employees #2 and #3 were transported by paramedics to Torrance Memorial Hospital for treatment; Employee #1 was transported to Bay Harbor Hospital.

Keywords: BURN, FLAMMABLE VAPORS, FIRE, EXPLOSION, GASOLINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112090543 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 112090543 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 112090543 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close